F-3

TROUBLESHOOTING & REPAIR

 

 

 

TROUBLESHOOTING GUIDE

 

 

Observe Safety Guidelines

 

 

 

 

 

 

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

 

 

MISADJUSTMENT(S)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

Major physical or electrical damage

 

 

Contact your LOCAL LINCOLN

 

 

Contact the Lincoln Electric Service

 

 

 

is evident.

 

 

 

AUTHORIZED FIELD SERVICE

 

 

Department. (216) 383-2531 or 1-

 

 

 

 

 

 

 

FACILITY.

 

 

800-833-9353 (WELD)

 

 

 

 

 

 

 

 

 

 

 

 

 

No wire feed, weld output or gas

 

 

1. Make sure correct voltage is

 

 

1. Check for 115 VAC at input to

 

 

 

flow when gun trigger is pulled. Fan

 

 

applied to the machine (115

 

 

fan motor (leads #31 to #32). If

 

 

 

does NOT operate.

 

 

 

vac).

 

 

correct voltage is present and fan

 

 

 

 

 

 

 

 

motor does not function, replace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Make certain that power switch

 

 

the fan motor. See wiring dia-

 

 

 

 

 

 

 

 

 

gram.

 

 

 

 

 

 

 

is in the ON position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. If 115 vac is not present at leads

 

 

 

 

 

 

 

 

 

 

#31 to #32, then check the power

 

 

 

 

 

 

 

 

 

 

switch and input line cord. (SI)

 

 

 

 

 

 

 

 

 

 

 

 

 

No weld output or wire feed when

 

 

Contact your LOCAL LINCOLN

 

 

1. Check voltage from leads #202

 

 

 

gun trigger is pulled. Fan runs and

 

 

AUTHORIZED FIELD SERVICE

 

 

to #201 at the output diode heat

 

 

 

gas flows normally.

 

 

 

FACILITY.

 

 

sinks. Normal voltage is from 2

 

 

 

 

 

 

 

 

 

 

vac to 20 VAC, depending on arc

 

 

 

 

 

 

 

 

 

 

voltage control setting. If the cor-

 

 

 

 

 

 

 

 

 

 

rect AC voltage is present, check

 

 

 

 

 

 

 

 

 

 

the output diodes and connec-

 

 

 

 

 

 

 

 

 

 

tions. Also check the output ca-

 

 

 

 

 

 

 

 

 

 

pacitor, C1. See wiring diagram.

 

 

 

 

 

 

 

 

 

 

2. If the correct AC voltage is not

 

 

 

 

 

 

 

 

 

 

present at the diode heat sink

 

 

 

 

 

 

 

 

 

 

leads #202 to #201, then check

 

 

 

 

 

 

 

 

 

 

the AC voltage on the trans-

 

 

 

 

 

 

 

 

 

 

former (TI) primary leads #531 to

 

 

 

 

 

 

 

 

 

 

#32 (normal is 115 vac with arc

 

 

 

 

 

 

 

 

 

 

voltage control at maximum). If

 

 

 

 

 

 

 

 

 

 

the correct voltage is present at

 

 

 

 

 

 

 

 

 

 

the transformer primaries (#531

 

 

 

 

 

 

 

 

 

 

to #32), the transformer may be

 

 

 

 

 

 

 

 

 

 

faulty. See wiring diagram.

 

 

 

 

 

 

 

 

 

 

3. If the correct voltage is not pre-

 

 

 

 

 

 

 

 

 

 

sent at leads #531 to #32, then

 

 

 

 

 

 

 

 

 

 

check the arc voltage control

 

 

 

 

 

 

 

 

 

 

potentiometer (RI)and associated

 

 

 

 

 

 

 

 

 

 

wires #205, #206 and #207 for

 

 

 

 

 

 

 

 

 

 

loose or broken connections.

 

 

 

 

 

 

 

 

 

 

See wiring diagram.

 

 

 

 

 

 

 

 

 

 

4. The control board may be faulty

 

 

 

 

 

 

 

 

 

 

– Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed call 216-383-2531 or 1-800-833-9353.

SP-100

Page 40
Image 40