Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

 

TROUBLESHOOTING & REPAIR

F-10

TYPICAL OUTPUT VOLTAGE WAVEFORM – MACHINE LOADED

C1

0 volts

10 volts

20 ms

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

This is the typical output voltage waveform generated from a properly operating machine. Note that each vertical division represents 10 volts and that each hor- izontal division represents 20 milliseconds in time. The machine was loaded with a resistance grid bank. The ammeter read 90 amps and the voltmeter read 19 vdc.

Note: Scope probes connected at machine output ter- minals. Positive probe to (+) terminal, negative probe to (–) terminal.

SCOPE SETTINGS

Volts/Div

10/Div

Horizontal Sweep

20 ms/Div

Coupling

DC

Trigger

Internal

 

 

SP-100