TROUBLESHOOTING & REPAIR

 

ABNORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

C1

0 volts

10 volts

20 ms

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

This is NOT the typical output voltage waveform. The output capacitor was disconnected from the circuit. Note the increased ripple in the waveform. This condi- tion simulates the faulty output filter capacitor. Each vertical division represents 10 volts and that each hor- izontal division represents 20 milliseconds in time.

Note: Scope probes connected at machine output ter- minals. Positive probe to (+) terminal, negative probe to (–) terminal.

SCOPE SETTINGS

Volts/Div

10/Div

Horizontal Sweep

20 ms/Div

Coupling

DC

Trigger

Internal

 

 