TROUBLESHOOTING & REPAIR

F-14

RETEST AFTER REPAIR

Should a machine under test be rejected for any reason requiring the removal of any mechani- cal part that could affect the machine’s electrical characteristics, or if any electrical components are repaired or replaced, the machine must be retested.

MAIN TRANSFORMER SECONDARY VOLTAGES

 

TEST POINTS

VOLTAGES

 

 

 

 

 

 

LEADS #201 – #202

2-20 vac Dependent on arc voltage control

 

 

Located on Output Diode Heat Sinks.

setting (min. to max.)

 

 

 

 

 

 

INPUT AMPS AT RATED OUTPUT

 

 

 

 

 

 

INPUT AMPS (AC)

@ OUTPUT (DC)

 

 

 

 

 

 

20 amps

90 amps @ 18 vdc

 

 

 

 

 

 

OPEN CIRCUIT VOLTAGES

 

 

 

 

 

 

TEST POINTS

VOLTAGES

 

 

 

 

 

 

OUTPUT TERMINALS

10 to 27 vdc Dependent on arc voltage

 

 

 

control setting (min. to max.)

 

 

 

 

 

 

WIRE SPEED RANGE

 

 

 

50 to 400 in /min.

 

Dependent on wire speed control setting

(1,2 to 10,2 m/min.)

 

 

 

 

 

12/95 SP-100