Lindy CPU IP Access Switch Plus Serial port configuration, Modem port, Power control port, 

Models: CPU IP Access Switch Plus

1 64
Download 64 pages 57.45 Kb
Page 51
Image 51
Serial port configuration

Serial port configuration

This page provides all access to settings concerned with the two serial ports (modem and power control) that are situated at the rear of the CPU IP.

To get here

1Using VNC viewer or a browser, log on as the ‘admin’ user.

2 Click the ‘Configure’ button in the top right corner. 3 Click the ‘Serial port configuration’ option.

Modem port

PPP server IP address / PPP client IP address

When a user dials into the CPU IP via a modem or ISDN adapter, the CPU IP sets up a temporary two-device network using PPP (Point to Point Protocol). For this purpose, both devices must have ‘dummy’ IP addresses so that they can communicate correctly. These two addresses can be almost anything expressed in the quad octet format (i.e. 192.168.3.1.). However, it is advisable not to make them the same as the real IP addresses used by either the remote system or the

CPU IP.

Baud rate

This option configures the speed of the serial connection between the CPU IP and a connected modem or ISDN terminal adapter. The default setting is 115200. The other communication settings are fixed as: No parity, 8 bit word, 1 stop bit.

Initialization sequence

The codes entered here are used to prepare the connected modem or ISDN terminal adapter for use with the CPU IP. The default code is a Hayes-compatible string to configure auto answer mode and would be understood by the vast majority of modem/ISDN devices. The code is sent when the CPU IP is first switched on or whenever the Initialize button is clicked.

Initialize

When clicked, this option sends the characters entered in the Initialisation sequence field to the connected modem or ISDN terminal adapter.

Restore Defaults

When clicked, this option resets the Baud rate and Initialisation sequence values to their original default settings.

Power control port

Baud rate

This option configures the speed of the serial connection between the CPU IP and a connected power control unit. The default setting is 9600 as used by the majority of power units. The other communication settings are fixed as: No parity, 8 bit word, 1 stop bit.

   



50

Page 51
Image 51
Lindy CPU IP Access Switch Plus Serial port configuration, Modem port, Power control port, , To get here, Baud rate