11.CUSTOMIZING THE SYSTEM

Adding additional sensors will increase the protection provided by the system.

All ground-level perimeter openings and accessible upper-story openings need protection.

Motion detectors can protect interior areas and areas where valuables are kept.

ADDING SENSORS TO THE SYSTEM

Always start with the Console in Test Mode (enter a user code and press [TEST]).

START IN TEST

Enter the master user code then press the [TEST] button.

A “gong” and five “beeps” will sound.

The sensor status indicators will light for each sensor programmed into the Console.

Enter an unused sensor number from 01-12 (you must enter two digits, example: 5 = 05).

NOTE: A sensor can be learned into more than one location. Be sure to choose an unused sensor number. If a sensor gets entered into more than one location, delete the duplicates using the remove sensor function.

The sensor indicator light will flash for the sensor number selected.

TEST

MASTER USER CODE

1 GONG &

5 BEEPS

NEW SENSOR NUMBER

Activate the sensor. (To add a wireless keypad, press the keypad’s [∗] key.)

A single “bing” tone will sound when the sensor is learned by the Console and the sensor status indicator will stay lit.

Enter another sensor number or exit Setup Mode by holding the [OFF] button for three seconds.

REMOVING SENSORS FROM THE SYSTEM

If a previously learned sensor isn’t going to be

used with the system anymore, or it’s a

duplicate that has been entered into more

than one sensor location, it should be

removed from the Console’s memory.

ACTIVATE

SENSOR

DONE

START IN TEST

Start with the Console in Test Mode.

Enter the master user code then press the [TEST] button.

A “gong” and five “beeps” will sound.

The sensor status indicators will light for each sensor programmed into the Console.

Enter the sensor number (from 01-12) that you want to remove (you must enter two digits, example: 5 = 05).

The sensor indicator light will flash for the sensor number selected.

Press the [TEST] button.

TEST

MASTER

USER

CODE

1 GONG &

5 BEEPS

SENSOR

NUMBER TO REMOVE

A single “bing” tone will sound when the sensor has been removed and the sensor status indicator will turn off.

Enter another sensor number or exit Setup Mode by holding the [OFF] button for three seconds.

TEST 1 BING

DONE

22