COMMUNICATOR REPORTING OPTIONS
REPORTING FORMAT
◆The factory setting causes the communicator to report using the 4 by 2 format. This format allows
◆Alternately ADEMCO CONTACT ID can be chosen as a reporting format. This format allows
1
0PROGRAMMING STEP #105
5JKL
PROGRAM
HOME
0 FOR 4 BY 2
1 FOR ADEMCO CONTACT ID
AWAY
STORE PROGRAM
CALL ROUTING
◆The factory setting for the communicator is to route all calls to the primary telephone number. If communication is unsuccessful after five attempts to the primary number, the secondary number will be dialed for an additional five attempts. If the secondary number cannot be reached, the communicator will “sleep” for five minutes before starting the call process over again. A total of five sleep cycles (50 call attempts) can occur before the communicator stops calling.
◆Alternately, the communicator can be programmed to report supervisory events (low batteries, radio trouble, AC failure, etc.) to the supervisory telephone number instead of the primary or secondary telephone numbers.
✍CAUTION: If the page alert user code feature is going to be used, the supervisory number is reserved for the pager number. DO NOT SET THE CALL ROUTING OPTION TO “1”.
◆To disable supervisory reports, set call routing option to “1” and remove the supervisory telephone number or in 4 by 2 set the report to “0”.
✍NOTE: Do not program the primary and secondary telephone numbers the same. See the FCC Telephone Rules and Regulations on the rear cover of this manual.
8TUV
6MNO
HOME
AWAY
PROGRAMMING STEP #86
PROGRAM
0 FOR ALL TO PRIMARY/SECONDARY 1 FOR ALARMS ONLY TO
PRIMARY/SECONDARY
STORE PROGRAM
COMMUNICATOR REPORTING OPTIONS
STEP # | PROGRAMMING |
| POSSIBLE | FACTORY VALUE | INSTALLATION |
| FUNCTION |
| VALUES |
| VALUE |
|
| 0 | = ALL CALLS TO PRIMARY OR SECONDARY NUMBER |
|
|
86 | CALL ROUTING | 1 | = ALL ALARM CALLS TO PRIMARY OR SECONDARY NUMBER AND | 0 |
|
|
| ALL OTHERS TO SUPERVISORY NUMBER |
|
| |
88 | ACCOUNT NUMBER | 4 DIGITS | EMPTY |
| |
89 | PRIMARY PHONE NUMBER | UP TO 20 DIGITS | EMPTY |
| |
90 | SECONDARY PHONE NUMBER | UP TO 20 DIGITS | EMPTY |
| |
91 | SUPERVISORY/ PAGER PHONE NUMBER | UP TO 20 DIGITS | EMPTY |
| |
|
| PRESSING THE (A) KEY INSERTS A |
|
| |
| FOR ALL PHONE NUMBERS ⇒⇒⇒⇒ | THE [FIRE] KEY INSERTS A |
|
| |
| THE [CHIME] KEY INSERTS A “*” |
|
| ||
|
|
|
| ||
|
| THE (A) KEY INSERTS A “#” IF IT IS THE LAST DIGIT OF THE PHONE NUMBER |
|
| |
105 | REPORTING FORMAT | 0 | = 4 BY 2; 1 = ADEMCO | 0 |
|
108 | REPORT CONSOLE TROUBLE | 0 | = NO; 1 = YES | 0 |
|
110 | REPORT FORCE ARMING | 0 | = NO; 1 = YES | 0 |
|
111 | OPEN/CLOSE | 0 | = NO; 1 = YES; 2 = MASTER PAC ONLY | 0 |
|
113 | POINT ID REPORTING FOR 4 BY 2 FORMAT | 0 | = NO; 1 = YES | 1 |
|
Communicator Reporting Option Table