4. CONSOLE FEATURES

5

4

3

2

6

7

1

8

124-HOUR BUTTONS

Pressing the [FIRE] button for two seconds sounds the fire siren and sends a “fire” message to a central monitoring station through the digital communicator (if the system is monitored).

Pressing the [EMERGENCY] button for two seconds sounds the emergency siren and sends an “emergency” message to a central monitoring station through the digital communicator (if the system is monitored).

Both work even when system is disarmed.

IMPORTANT: For personal emergency use only. Not for use as a UL Listed Medical Alert System.

2MODE BUTTONS

Used to control the Console.

OFF

Off Mode disarms the system.

Switching to Off Mode stops the alarm siren.

Multiple beeps sound and status lights flash if an alarm has occurred.

Multiple beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.

CHIME

Chime Mode disarms the system.

Switching to Chime Mode stops the alarm siren.

Multiple beeps sound and status lights flash if an alarm has occurred.

Multiple beeps mean caution. AN INTRUDER MAY STILL BE PRESENT.

Chime Mode is for monitoring doors and windows.

Use this mode as an “automatic door chime” when at home.

Opening any protected door or window causes Console to “ding-dong”.

HOME

Home Mode arms the perimeter sensors, but not the interior sensors.

Use this mode when anyone is staying behind.

Interior motion detectors and interior door sensors are not armed.

Home secure mode makes all delayed perimeter sensors instant.

Secure exit mode starts an exit delay while remaining in Home Mode.

Re-entering during the exit delay restarts the exit delay (one time only).

AWAY

Away Mode arms the entire system.

Use this mode when leaving home.

Door sensors set for delayed will have a delay that allows you to leave and enter the premises without sounding the alarm.

Re-entering during the exit delay restarts the exit delay (one time only).

Entry Delay beeps warn you to disarm the system before the siren starts.

TEST

Test Mode is for testing the system sensors.

All sensor status lights blink when the Test Mode is entered.

Each sensor status light will stop blinking when its sensor is tested.

Hold the [TEST] button down to test all of the Console’s indicator lights.

3MODE INDICATORS

Specific indicator will light showing the mode the Console is in.

HOME indicator will blink during secure exit and home instant modes.

AWAY indicator will blink during the exit delay in the Away Mode.

4CONSOLE STATUS INDICATORS

Show the current status of the Console.

POWER LIGHT

Glows when AC power is on.

Dims when AC power is off and backup battery is installed.

Blinks when the backup battery is low, recharging or missing.

Off when AC power is off and no backup battery is installed (system disabled).

BATTERIES LIGHT

Blinks when one or more sensors has a low battery.

Press [] key for one second to view sensor status. Sensor status indicator for any sensor with a low battery will light along with the BATTERIES indicator. Any trouble indications will follow during the five second status cycle.

Switch to Test Mode after replacing the sensor battery and completely test the system (see Test Mode). Switching to Test Mode clears the low battery indication.

TROUBLE LIGHT

Blinks when one or more sensors have not reported status during the eight hour status time window.

Press [] key for one second to view sensor status. Sensor status indicator for any sensor that has not reported in will light along with the TROUBLE indicator. Any low battery indications will follow during the five second status cycle.

Switch to Test Mode after servicing the sensor and completely test the system (see Test Mode). Switching to Test Mode clears the trouble indication.

5SIREN SPEAKER

Makes unique sounds for burglary, fire and emergencies.

Alarm sirens stop automatically after five minutes.

Sounds advisory tones to confirm keystrokes from the Console.

Sounds mode selections tones.

Sounds alarm memory tones.

Beeps when Automation Output is activated.

Terminals available for an external siren.

6STATUS INDICATORS

Indicates the status of each of the system’s sensors.

Lights show which doors and windows are open.

Lights flash to display sensors that have caused an alarm.

Stick-on labels are provided to identify the custom sensor locations.

7CASE ACCESS SCREW (HIDDEN)

Remove clear display window and sensor identification card to gain access to the screw.

Remove case access screw to unlock case. Case hinges open to the left.

8KEYPAD

For entering the user’s user code (numerically or alphabetically).

Used when programming system options.

Press [(A)] key to activate Automation Output.

Press the [] key to clear keypad if the wrong key is pressed.

Press and hold the [] key for one second to view sensor battery and supervisory status (see BATTERIES and TROUBLE indicator description).

6