4 BY 2 FORMAT POINT ID REPORTING CODES

4 BY 2 FORMAT POINT ID ALARM REPORT CODES

Refer to the 4 by 2 Format Point ID Reporting Code table to view/edit the alarm reporting

codes for each of the 12 sensors. The

DVS12K24.EPS

communicator will send these codes if Point

 

 

 

 

ID is enabled and any sensor triggers an

PROGRAMMING STEPS

 

alarm. The factory settings are listed, along

#210 TO #221

 

 

 

with a blank area to write in the new

 

 

installation values.

PROGRAM

 

NOTE: Be careful not to duplicate codes unless

0 - 99 FOR SENSOR

 

the Central Station requires specific codes for

 

ALARM CODE

 

certain types of sensors.

(0 = NO REPORT)

 

Each programming function is performed with

STORE PROGRAM

 

similar keystrokes. After the system is in

 

 

 

 

Setup Mode, enter the programming step

 

 

number, press the [HOME] key (HOME =

 

 

program), enter the new value, and press the

 

 

[AWAY] key (AWAY = store).

 

 

 

 

 

4 BY 2 FORMAT POINT ID TROUBLE REPORT CODES

 

 

Refer to the 4 by 2 Format Point ID Reporting

Code table to view/edit the trouble reporting

PROGRAMING STEPS

codes for each of the 12 sensors. The

#234 TO 245

communicator will send these codes if Point

 

ID is enabled and any sensor has a low battery

 

or trouble condition. The factory settings are

PROGRAM

 

listed, along with a blank area to write in the

0 - 99 FOR SENSOR

new installation values.

TROUBLE CODE

NOTE: Be careful not to duplicate codes unless

(0 = NO REPORT)

STORE PROGRAM

the Central Station requires specific codes for

certain types of sensors.

Each programming function is performed with similar keystrokes. After the Console is in Setup Mode, enter the programming step number, press the [HOME] key (HOME = program), enter the new value, and press the [AWAY] key (AWAY = store).