MAKING A SENSOR ACTIVATE A DIFFERENT ZONE
◆Any sensor can be reprogrammed to activate any of the Console’s zones.
◆The sensor must have already been learned by the Console (see “Adding sensors to the System” for details).
Start with the Console in Test Mode. Enter the master user code then press the [TEST] button.
❇A “gong” and five “beeps” will sound.
❇The sensor status indicators will light for each sensor programmed into the Console.
Enter the sensor number from
❇The sensor indicator light will flash for the sensor number selected.
Choose a zone number from the Console Zone Table.
Press [HOME], the new zone number, then [AWAY]. A “bing” tone will sound.
Enter another sensor number or exit Setup Mode by holding the [OFF] button for three seconds.
START IN TEST
MASTER
USER
CODE
TEST | 1 GONG & | |
5 BEEPS | ||
| ||
| SENSOR | |
| NUMBER | |
| FOR ZONE | |
| CHANGE | |
HOME |
| |
| ZONE | |
| NUMBER | |
AWAY | 1 BING | |
|
DONE
PROGRAMMING INFORMATION |
| SENSOR FUNCTION IN EACH CONSOLE MODE |
| |||
|
|
|
|
|
|
|
ZONE # | SENSOR TYPE | OFF MODE | CHIME MODE |
| HOME MODE | AWAY MODE |
|
|
|
|
|
| |
1 | AUTOMATION |
| ACTIVATES AND DEACTIVATES THE AUTOMATION OUTPUT |
| ||
2 | EMERGENCY |
| ARMED |
| ||
3 | PANIC |
| ARMED |
| ||
4 | FIRE |
| ARMED |
| ||
5 | PERIMETER | DEACTIVATED | CHIME |
| INSTANT BURGLARY ALARM | |
6 | EXIT/ENTRY | DEACTIVATED | CHIME |
| DELAYED BURGLARY ALARM | |
|
|
|
|
|
| FOLLOWER |
7 | INTERIOR | DEACTIVATED | DEACTIVATED |
| DEACTIVATED | (INSTANT BURGLARY ALARM |
| UNLESS ACTIVATED DURING | |||||
|
|
|
|
|
| |
|
|
|
|
|
| ENTRY DELAY) |
8 | CHIME |
|
| CHIME |
| |
|
| LEFT BUTTON SWITCHES CONSOLE TO AWAY OR HOME |
|
|
| |
9 | MODE (PROGRAMMING FUNCTION 50) |
| LEFT BUTTON SWITCHES TO OFF OR CHIME MODE | |||
IF ALARM IS ACTIVE, SWITCHES CONSOLE TO OFF OR |
| (PROGRAMMING FUNCTION 51) | ||||
|
| |||||
|
| CHIME MODE (PROGRAMMING FUNCTION 51) |
|
|
| |
|
| LEFT BUTTON SWITCHES CONSOLE TO AWAY OR HOME |
|
|
| |
10 | MODE (PROGRAMMING FUNCTION 50) |
| RIGHT BUTTON SWITCHES TO OFF OR CHIME MODE | |||
IF ALARM IS ACTIVE, SWITCHES CONSOLE TO OFF OR |
| (PROGRAMMING FUNCTION 51) | ||||
|
| |||||
|
| CHIME MODE (PROGRAMMING FUNCTION 51) |
|
|
| |
11 | ENVIRONMENTAL |
| ARMED |
|
Console Zone Table
24