COMMUNICATOR REPORTING CODES
◆The
◆If Point ID reporting is enabled (the factory
default setting), each sensor can report a | HOME = PROGRAM | TEST = REMOVE | |
unique alarm and trouble code. |
|
| |
◆ If Point ID is disabled, the “general” reporting | AWAY | = STORE | |
codes for each event type will be used. | |||
|
|
◆Each programming function is performed with similar keystrokes. After the Console is in Setup Mode, enter the programming step number, press the [HOME] key (HOME = program), enter the new value, and press the [AWAY] key (AWAY = store).
◆Making a value 0 causes event to not communicate to central station.
✍NOTE: The reporting codes are fixed for opening and closing. A unique code is reserved for the master, the five restricted, and page alert user codes. See the Opening & Closing Reporting Codes Table.
GENERAL REPORTING CODES
◆Program Steps #201 - 206 for the communicator reporting codes when Point ID is disabled.
◆Refer to the Console & General Reporting Codes table to view/edit the reporting codes for each of the five events. The factory settings are listed, along with a blank area to write in the new installation values.
◆Any value from
✍NOTE: Be careful not to duplicate codes unless the Central Station requires specific codes for certain types of events.
2ABC
PROGRAMMING STEPS
0#201 TO #206
HOME PROGRAM
0 - 99 FOR GENERAL ALARM REPORTING CODE
AWAY STORE PROGRAM
SYSTEM REPORTING CODES
◆Program Steps #261 - 266 for the Console reporting codes.
◆Refer to the System Reporting Codes table to view/edit the reporting codes for the keypad [FIRE] and [EMERGENCY] buttons and for each of the four Control Panel conditions. The factory settings are listed, along with a blank area to write in the new installation values.
2 ABC
PROGRAMMING STEPS
6 MNO | #261 TO #266 |
|
HOME PROGRAM
0 - 99 FOR SYSTEM REPORTING CODE
AWAY STORE PROGRAM
GENERAL REPORTING CODES
STEP # | PROGRAMMING |
| POSSIBLE | FACTORY | INSTALLATION |
FUNCTION |
| VALUES | VALUE | VALUE | |
|
| ||||
|
|
|
|
|
|
201 | GENERAL FIRE REPORT CODE |
| 0 - 99 | 1 |
|
202 | GENERAL EMERGENCY REPORT CODE |
| 0 - 99 | 2 |
|
203 | GENERAL SILENT PANIC REPORT CODE |
| 0 - 99 | 3 |
|
204 | GENERAL BURGLARY REPORT CODE |
| 0 - 99 | 4 |
|
206 | GENERAL TROUBLE REPORT CODE |
| 0 - 99 | 6 |
|
|
| General Reporting | Codes Table |
|
|
38