ADDITIONAL USER CODES

The Console can be programmed with five restricted user codes and one page alert user code.

The additional codes operate the system as usual, but cannot access Setup Mode.

The additional codes can access a special Code Mode that can be used to change or remove any of the five restricted user codes, the page alert user code, or the duress code.

The page alert user code dials the supervisory number (programmed for a pager) when it is used to disarm the system.

NOTE: For maximum security, a 3-5 digit code is recommended.

WARNING: NEVER PROGRAM ANY RESTRICTED OR PAGE ALERT USER CODE THE SAME AS THE MASTER USER CODE!

Log the user codes in the boxes to the right.

PROGRAMMING STEPS #93 TO 98

PROGRAM

1-5 DIGIT CODE

(3-5 DIGITS RECOMMENDED)

STORE PROGRAM

STEP # 93 RESTRICTED USER CODE #1

STEP # 94 RESTRICTED USER CODE #2

STEP # 95 RESTRICTED USER CODE #3

STEP # 96 RESTRICTED USER CODE #4

STEP # 97 RESTRICTED USER CODE #5

STEP # 98 PAGE ALERT USER CODE

REMOVING USER CODES

Any restricted, duress or page alert user code can be removed from the Console.

Because access to programming would be impossible without a master user code, it cannot be removed using these steps.

The master user code can be changed using programming Step #99.

NOTE: The master user code can be removed using the Console master reset, although all other system programming with be reset to factory values and all sensors programmed will be erased.

9 WXY KEYPAD CODE PROGRAMMING STEPS #92 TO 98

TEST REMOVE

CONSOLE MASTER RESET

Master resetting the Console will set all of the

programming options back to the factory

values. The master user code will be reset to

START IN TEST

1234.

CAUTION: Master resetting the Console will erase the user codes, and remove all programmed sensors. All Console and communicator programming values will be reset to the factory defaults.

TEST

MASTER USER CODE

1 GONG &

5 BEEPS

Start with the system in Test Mode (Setup Mode cannot be reached from any other mode).

From the Test Mode, enter the master user code then press [TEST].

A “Gong” and five “Beeps” will sound, signaling that the system is in Setup Mode.

Enter programming Step #999.

Press [TEST].

Enter the numbers 999 again.

Press [TEST] again.

A “Bing” will sound to indicate the beginning of the reset process. This process will take up to 10 seconds while the memory is being reset.

9WXY

 

STEP #999

 

9 WXY

FOR

USE THESE EXACT

MASTER

 

KEYSTROKES

 

RESET

 

TO PERFORM A

9 WXY

 

 

MASTER RESET

 

 

TEST

PRESS

 

TEST

 

 

 

9WXY

ENTER 999

9 WXY TO OK THE MASTER

RESET

9WXY

The system will revert to the first time

power-up condition and the master user code

will be 1234. Go to the “Basic Console

Programming” section of this manual to begin

TEST

PRESS TEST,

1 BING SOUNDS, WAIT ABOUT 10 SECONDS

re-programming the system.

DONE

31