CHANGING A SENSORS SUPERVISION

 

 

When a sensor is programmed, the Console

 

SENSOR NUMBER

automatically recognizes it as supervised or

 

TO CHANGE

 

 

non-supervised.

HOME

PROGRAM

The Console expects hourly status transmissions

 

 

from any sensor programmed as supervised.

 

16 FOR NON-SUPERVISED

Any sensor can be programmed as supervised

 

17 FOR SUPERVISED

 

 

or non-supervised.

AWAY

STORE PROGRAM

NOTE: Don’t program a sensor that doesn’t send

 

 

status transmissions as supervised.

 

 

CHANGING A SENSORS RESTORE REQUIREMENTS

 

 

When a sensor is programmed, the Console

 

SENSOR NUMBER

automatically recognizes it as manually or

 

TO CHANGE

automatically restoring.

HOME

PROGRAM

The Console expects restoral signals from any

 

 

sensor programmed as manual restore.

 

18 FOR MANUAL RESTORE

Any sensor can be programmed as manual or

 

19 FOR AUTO RESTORE

 

 

automatic restore.

AWAY

STORE PROGRAM

NOTE: Don’t program a sensor that doesn’t send

 

 

restoral transmissions as manual restore.

 

 

ENTRY DELAY TIME

 

 

The factory-set Entry Delay time is 30 seconds.

 

PROGRAMMING STEP #25

The Entry Delay time can be adjusted from 20

 

 

to 255 seconds.

 

PROGRAM

NOTE: Don’t make the Entry Delay too short. The

 

 

user may not have enough time to disarm the

 

TIME IN SECONDS (20-255)

system before an alarm.

 

 

 

Write the new Entry Delay time in the User’s Guide.

 

STORE PROGRAM

 

 

EXIT DELAY TIME

The factory-set Exit Delay time is 60 seconds.

The Exit Delay time can be adjusted from 20 to 255 seconds.

Write the new Exit Delay time in the User’s Guide.

PROGRAMMING STEP #26

PROGRAM

TIME IN SECONDS (20-255)

STORE PROGRAM

BURGLARY SIREN TIME

The factory-set burglary siren time is five minutes (UL installation maximum).

The burglary siren time can be adjusted from one to 30 minutes.

3DEF

PROGRAMMING STEP #30

0

 

HOME

PROGRAM

 

TIME IN MINUTES (1-30)

AWAY

STORE PROGRAM

EMERGENCY SIREN TIME

The factory-set emergency siren time is five minutes (UL installation maximum).

The emergency siren time can be adjusted from one to 30 minutes.

3DEF

PROGRAMMING STEP #31

1

HOME PROGRAM

TIME IN MINUTES (1-30)

AWAY STORE PROGRAM

26