Chapter 5 Linksys IP Phone Field Reference

SIP Tab

Field

Description

 

 

INFOREQ Dynamic Payload

INFOREQ dynamic payload type.

(not applicable to SPA901)

Defaults to blank.

 

 

G726r16 Dynamic Payload

G.726-16 dynamic payload type. Ranges from 96-127.

 

Defaults to 98.

 

 

G726r24 Dynamic Payload

G.726-24 dynamic payload type. Ranges from 96-127.

 

Defaults to 97.

 

 

G726r32 Dynamic Payload

G726r32 dynamic payload type.

(not applicable to SPA901)

Defaults to 2.

 

 

G726r40 Dynamic Payload

G.726-40 dynamic payload type. Ranges from 96-127.

 

Defaults to 96.

 

 

G729b Dynamic Payload

G.729b dynamic payload type. Ranges from 96-127.

 

Defaults to 99.

 

 

EncapRTP Dynamic Payload

EncapRTP Dynamic Payload type.

(not applicable to SPA901)

Defaults to 112.

 

 

RTP-Start-Loopback Dynamic

RTP-Start-Loopback Dynamic Payload.

(not applicable to SPA901)

Defaults to 113.

 

 

RTP-Start-Loopback Codec

RTP-Start-Loopback Codec. Select one of following: G711u, G711a, G726-16, G726-24,

(not applicable to SPA901)

G726-32, G726-40, G729a, or G723.

Defaults to G711u.

 

 

 

AVT Codec Name

AVT codec name used in SDP.

(not applicable to SPA901)

Defaults to telephone-event.

 

 

G711u Codec Name

G.711u codec name used in SDP.

(not applicable to SPA901)

Defaults to PCMU.

 

 

G711a Codec Name

G.711a codec name used in SDP.

(not applicable to SPA901)

Defaults to PCMA.

 

 

G726r16 Codec Name

G.726-16 codec name used in SDP.

(not applicable to SPA901)

Defaults to G726-16.

 

 

G726r24 Codec Name

G.726-24 codec name used in SDP.

(not applicable to SPA901)

Defaults to G726-24.

 

 

G726r32 Codec Name

G.726-32 codec name used in SDP.

(not applicable to SPA901)

Defaults to G726-32.

 

 

G726r40 Codec Name

G.726-40 codec name used in SDP.

(not applicable to SPA901)

Defaults to G726-40.

 

 

 

 