Example 3-2 Asterisk Subscribecontext for SPA932

[3500]

type=friend

secret=3500

callerid="spa3500"<3500>

nat=no

context=home

mailbox=3500

Subscribecontext=home

...

...

Configuring the SPA932

Complete the configuration required for the extensions on your SPA9000 IP PBX and obtain the following information, which is required to configure the SPA932:

SPA9000 IP address (or hostname if supported)

Phone extension numbers

By default, all LEDs on the SPA932 are assigned to the first configured extension on the SPA962 to which it is connected. You need to assign the LEDs to any of the other five extensions on the SPA962 that you want to monitor using the SPA932.

To configure the SPA932, perform the following steps:

Step 1 Connect to the administration web server for the SPA962 to which the SPA932 is connected.

To use the SPA962 with a SPA932, it must be running Release 5.1.12 or later. Step 2 Click Admin/Advanced on the administration web server page.

Step 3 Click the SIP tab.

Step 4 Select yes from the CTI Enable pull-down selection list. Step 5 (optional) Change the SPA962 station name.

Click the Phone tab and edit the Station Name parameter in the General section. Step 6 Click the SPA932 tab.