Table 8.2

BIOS Boot Error Messages (Cont.)

 

 

 

 

Message

 

Problem

Suggested Solution

 

 

 

X Logical Drives

x number of logical

Make sure all physical drives are properly

Degraded

 

drives signed on in a

connected and are powered on.

 

 

degraded state.

Run MegaRAID Manager to find if any physical

 

 

 

 

 

 

drives are not responding. Reconnect, replace,

 

 

 

or rebuild any drive that is not responding.

 

 

 

1 Logical Drive

A logical drive signed on

Make sure all physical drives are properly

Degraded

 

in a degraded state.

connected and are powered on.

 

 

 

Run MegaRAID Manager to find out if any

 

 

 

physical drives are not responding. Reconnect,

 

 

 

replace, or rebuild any drive that is not

 

 

 

responding.

 

 

 

Insufficient memory to

Not enough MegaRAID

Make sure MegaRAID memory has been

run BIOS. Press any key

memory to run

properly installed.

to continue…

 

MegaRAID BIOS.

 

 

 

 

Insufficient Memory

Not enough memory on

Make sure MegaRAID memory has been

 

 

the MegaRAID adapter

properly installed.

 

 

to support the current

 

 

 

configuration.

 

 

 

 

The following SCSI IDs

The physical drives with

Make sure the physical drives are properly

are not responding:

SCSI IDs a, b, and c are

connected and are powered on.

Channel x:a.b.c

not responding on SCSI

 

 

 

channel x.

 

 

 

 

 

8-4Troubleshooting

Copyright © 2002 by LSI Logic Corporation. All rights reserved.