Table 8.2 | BIOS Boot Error Messages (Cont.) | ||
|
|
|
|
Message |
| Problem | Suggested Solution |
|
|
| |
X Logical Drives | x number of logical | Make sure all physical drives are properly | |
Degraded |
| drives signed on in a | connected and are powered on. |
|
| degraded state. | Run MegaRAID Manager to find if any physical |
|
|
| |
|
|
| drives are not responding. Reconnect, replace, |
|
|
| or rebuild any drive that is not responding. |
|
|
| |
1 Logical Drive | A logical drive signed on | Make sure all physical drives are properly | |
Degraded |
| in a degraded state. | connected and are powered on. |
|
|
| Run MegaRAID Manager to find out if any |
|
|
| physical drives are not responding. Reconnect, |
|
|
| replace, or rebuild any drive that is not |
|
|
| responding. |
|
|
| |
Insufficient memory to | Not enough MegaRAID | Make sure MegaRAID memory has been | |
run BIOS. Press any key | memory to run | properly installed. | |
to continue… |
| MegaRAID BIOS. |
|
|
|
| |
Insufficient Memory | Not enough memory on | Make sure MegaRAID memory has been | |
|
| the MegaRAID adapter | properly installed. |
|
| to support the current |
|
|
| configuration. |
|
|
|
| |
The following SCSI IDs | The physical drives with | Make sure the physical drives are properly | |
are not responding: | SCSI IDs a, b, and c are | connected and are powered on. | |
Channel x:a.b.c | not responding on SCSI |
| |
|
| channel x. |
|
|
|
|
|
Copyright © 2002 by LSI Logic Corporation. All rights reserved.