8.3Other BIOS Error Messages
Table 8.3 describes other BIOS error messages, their meaning, and suggested solutions.
Table 8.3 | Other BIOS Error Messages |
| |
|
|
|
|
Message |
| Problem | Suggested Solution |
|
|
| |
Following SCSI disk | The physical disk roaming | Reconfigure the array. | |
not found and no | feature did not find the |
| |
empty slot available | physical disk with the |
| |
for mapping it |
| displayed SCSI ID. No slot is |
|
|
| available to map the physical |
|
|
| drive. MegaRAID cannot |
|
|
| resolve the physical drives |
|
|
| into the current configuration. |
|
|
|
| |
Following SCSI IDs | The physical drive roaming | Remove the drive or drives that should not | |
have the same data y, | feature found the same data | be used. | |
z |
| on two or more physical drive |
|
Channel x: a, b, c | on channel x with SCSI IDs a, |
| |
|
| b, and c. MegaRAID cannot |
|
|
| determine the drive that has |
|
|
| the duplicate information. |
|
|
|
|
|
Unresolved |
| The configuration stored in the | 1. Press a key to run MegaRAID Manager. |
configuration |
| MegaRAID NVRAM does not | 2. Select View/Add Configuration from the |
mismatch between | match the configuration stored | Configure menu. | |
disks and NVRAM on | on the drives. | 3. Use View/Add Configuration to examine | |
the adapter |
|
| |
|
| both the configuration in NVRAM and the | |
|
|
| |
|
|
| configuration stored on the disk drives. |
|
|
| 4. Resolve the problem by selecting one of |
|
|
| the configurations. |
|
|
|
|
|
|
|
|
8.4Other Potential Problems
| Table 8.4 describes other potential problems. | |
Table 8.4 | Other Potential Problems | |
|
|
|
Topic |
| Information |
|
|
|
DOS ASPI |
| MEGASPI.SYS, the MegaRAID DOS ASPI manager, uses 6 Kbytes of system |
|
| memory once it is loaded. |
|
|
|
Other BIOS Error Messages |
Copyright © 2002 by LSI Logic Corporation. All rights reserved.