8.3Other BIOS Error Messages

Table 8.3 describes other BIOS error messages, their meaning, and suggested solutions.

Table 8.3

Other BIOS Error Messages

 

 

 

 

 

Message

 

Problem

Suggested Solution

 

 

 

Following SCSI disk

The physical disk roaming

Reconfigure the array.

not found and no

feature did not find the

 

empty slot available

physical disk with the

 

for mapping it

 

displayed SCSI ID. No slot is

 

 

 

available to map the physical

 

 

 

drive. MegaRAID cannot

 

 

 

resolve the physical drives

 

 

 

into the current configuration.

 

 

 

 

Following SCSI IDs

The physical drive roaming

Remove the drive or drives that should not

have the same data y,

feature found the same data

be used.

z

 

on two or more physical drive

 

Channel x: a, b, c

on channel x with SCSI IDs a,

 

 

 

b, and c. MegaRAID cannot

 

 

 

determine the drive that has

 

 

 

the duplicate information.

 

 

 

 

 

Unresolved

 

The configuration stored in the

1. Press a key to run MegaRAID Manager.

configuration

 

MegaRAID NVRAM does not

2. Select View/Add Configuration from the

mismatch between

match the configuration stored

Configure menu.

disks and NVRAM on

on the drives.

3. Use View/Add Configuration to examine

the adapter

 

 

 

 

both the configuration in NVRAM and the

 

 

 

 

 

 

configuration stored on the disk drives.

 

 

 

4. Resolve the problem by selecting one of

 

 

 

the configurations.

 

 

 

 

 

 

 

 

8.4Other Potential Problems

 

Table 8.4 describes other potential problems.

Table 8.4

Other Potential Problems

 

 

 

Topic

 

Information

 

 

 

DOS ASPI

 

MEGASPI.SYS, the MegaRAID DOS ASPI manager, uses 6 Kbytes of system

 

 

memory once it is loaded.

 

 

 

Other BIOS Error Messages

8-5