•A combination of any two of the above conditions
2.3.3Consistency CheckA consistency check verifies the correctness of redundant data in a RAID array. For example, in a system with distributed parity, checking consistency means computing the parity of the data drives and comparing the results to the contents of the parity drives.
2.3.4Fault ToleranceFault tolerance is achieved through cooling fans, power supplies, and the ability to hot swap drives. MegaRAID SCSI
After the hot spare is automatically moved into the RAID subsystem, the failed drive is automatically rebuilt. The RAID disk array continues to handle request while the rebuild occurs.
2.3.5Disk StripingDisk striping writes data across multiple disk drives instead of just one disk drive, as shown in Figure 2.1.
Introduction to RAID |