Table 5.3 Physical Device Layout (Cont.)
Channel 0 | Channel 1 |
Target ID
Device type
Logical drive number/Drive number
Manufacturer/Model number
Firmware level
5.2Configuring Arrays
Connect the physical drives to the MegaRAID SCSI
For the MegaRAID SCSI
5.2.1Arranging Arrays
You must arrange the arrays to provide additional organization for the drive array. You must arrange arrays so that you can create system drives that can function as boot devices.
You can sequentially arrange arrays with an identical number of drives so that the drives in the group are spanned. Spanned drives can be treated as one large drive. Data can be striped across multiple arrays as one logical drive.
You can create spanned drives by using the MegaRAID Configuration Utility or the MegaRAID Manager. See the MegaRAID Configuration Software Guide for additional information.
Configuring Arrays |
Copyright © 2002 by LSI Logic Corporation. All rights reserved.