6.You can now add or remove DRAM modules from the MegaRAID controller, as described above.

7.Reattach the battery pack harness to J10 on the MegaRAID controller.

8.Reinstall the MegaRAID controller in the computer. Follow the instructions in this chapter.

9.Replace the computer cover and turn the computer power on.

6.2.3.2Recommended Memory Vendors

Call LSI Logic Technical Support at 678-728-1250 for a current list of recommended memory vendors.

6.2.4Step 4: Check Jumper Settings

Make sure the jumper settings on the MegaRAID SCSI 320-2 card are correct. The jumpers are set at the factory and you probably do not need to change them. Table 6.2 lists the jumpers that you should check.

Table 6.2

Jumpers for the MegaRAID SCSI 320-2

 

 

 

Item

Description

Type

 

 

 

J2

SCSI activity LED connector

4-pin header

 

 

 

J3

Write pending indicator

2-pin header

 

 

 

J4

SCSI Termination Enable Channel 0

3-pin header

 

 

 

J5

SCSI Termination Enable Channel 1

3-pin header

 

 

 

J10

Battery connector

3-pin header

 

 

 

J16

BIOS Enable

2-pin header

 

 

 

J17

Termination Power Channel 0

2-pin header

 

 

 

J18

Termination Power Channel 1

2-pin header

 

 

 

Figure 6.2 shows the location of these items on the MegaRAID SCSI 320-2 controller.

Installation Steps

6-5

Copyright © 2002 by LSI Logic Corporation. All rights reserved.