4.Push the inboard rollstop back against the lock as if a wheel- chair is pushing on the rollstop FIG. 47-1).

IBRS

PUSH IBRS AGAINST LOCK

FAX (888) 771-7713

5.On the inboard rollstop switch, loosen screws (1) and (2) one-half turn (FIG. 47-2B). Next, rotate switch bracket clockwise until the switch activates with an audible “click”. Then tighten screws (1) and (2) securely.

SWITCH

(REF)

SWITCH

BRACKET

POWER SWITCH

6.Turn ON power switch on pump cover (FIG. 47-2A). Then raise (UP) the platform to floor level (FIG. 46-1). Verify that “INBD SW” is not displayed on the lift controller. If necessary repeat this procedure.

PLATFORM BELOW FLOOR LEVEL, WITH IBRS UP (LH SIDE SHOWN)

FIG. 47-1

SCREW (2)

SCREW (1)

CUT-AWAY VIEW OF LH VERTICAL ARM & IBRS SWITCH FIG. 47-2B

PLATFORM BELOW FLOOR LEVEL, WITH IBRS UP (LH SIDE SHOWN)

FIG. 47-2A

11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116

47

PATENTS PENDING

Page 47
Image 47
Maxon Telecom WL7-VERS. C-1K installation instructions Platform below Floor LEVEL, with Ibrs UP LH Side Shown