MicroNet Technology SP5052A/S Parameter Usages, number instead of Line number of FXO Line+ PSTN

Models: SP5052A/S

1 57
Download 57 pages 36.88 Kb
Page 32
Image 32

-flashtime Flash time setting.(1-200, 1->10ms)

Example: sysconf -ring 500

---------------------------------------------------------------

Parameter Usages:

-idtime

set the duration (in second) of two pressed digits in dial mode

 

as timed out. If after the duration user hasn’t pressed next

 

number, it will dial out all number pressed. (1-10 seconds)

-keypad

keypad type when relay DTMF signal.

 

0 Æ In-Band

 

1 Æ RFC2833.

 

1. number (instead of Line number of FXO Line)+ PSTN

 

number to make a call to PSTN side connected with FXO

 

Line.

 

2. After gateway-prefix-drop function is enabled, user must

 

remember to re-configure line number of FXS Line,

 

because line number of FXS Line must remove prefix

 

number. For example, origin line number of FXS line is

 

1001, prefix is 100, since prefix number will be drop, once

 

gateway has incoming call 1001, after drop gateway prefix

 

100, it will search line number “1”. So line number must be

 

set as “1”.

-callerid

Support FSK and ETSI caller ID function. After the first ring

 

destination site, device will send line number as caller ID to

 

called site. It only supports on Hotline mode.

-ring

ring time for ring detection (in ms). When Gateway has

 

incoming call from PSTN side to FXO port, Gateway will

 

determine it is a ring but not noise only if it is longer than this

 

ring time.

Note: In Taiwan, the ring time of PSTN usually is 1000ms, so if user set ring time longer that 1000ms, FXO port may not be able to pick up the call from PSTN side.

-delay

When FXO port has an incoming call from IP side and signal

 

connection is established, it will wait the dial tone from PSTN

 

or PBX. But sometimes the dial tone from PBX is too late so

 

some errors will occur. Now user can use this command to