•4-ch Isolated Digital Input (DI0~DI3)
-2,000 VDC isolation
-2,000 VDC ESD protection
-70 VDC
-
-Input Voltage Range:
Logic 0:
Logic 1:
- Input Current:
10 VDC: 1.7 mA (typical)
12 VDC: 2.1 mA (typical)
24 VDC: 4.4 mA (typical)
48 VDC: 9.0 mA (typical)
50 VDC: 9.4 mA (typical)
-Interrupt handling capability
•4-ch Isolated Digital Output (DO0~DO3)
-2,000 VDC isolation and 200 mA max / channel sink current
-2 options after hot reset: Reset all digital output or keep last status
-5 ~ 40 VDC output range and 10 kHz speed
•Two 16-bit Counters/Timers:
-Counter source: DI1 & DI3, Pulse output: DO2 & DO3
-Can be cascaded as one
-Down counting, preset counting value
-Interrupt handling, speed: 40 kHz
-Internal timer time base: 100 kHz, 10 kHz, 1 kHz, 100 Hz
•HDD: HDD extension kit for installation of one standard 2.5” (optional)
•Anti-Shock:
20 G @ Wall mounting, IEC 68 section
•Anti-Vibration:
2 Grms w/CF@IEC 68 sec.
6 |