Miller Electric OM-230 manual Routine Maintenance, Unit Overload

Models: OM-230

1 52
Download 52 pages 27.6 Kb
Page 33
Image 33

.A complete Parts List is available at www.MillerWelds.com

SECTION 6 − MAINTENANCE &TROUBLESHOOTING

6-1. Routine Maintenance

!

Disconnect power

. Maintain more often

 

before maintaining.

during severe conditions.

n = Check

Z = Change

~ = Clean

l = Replace

* To be done by Factory Authorized Service Agent

 

Every

3 Months

 

l Unreadable Labels

~ Weld Terminals

nl Weld Cables

Every

 

 

 

6

OR

 

 

Months

 

 

 

 

 

 

~ Inside Unit

n Apply Light Coat Of Oil

 

 

 

Or Grease To Drive Motor

 

 

 

Shaft

 

Reference

6-2. Unit Overload

Thermistor T in SCR1 protects the unit from damage due to overheating. If HL.P 002 is displayed on the meters, wait for unit to cool allowing fan motor to run before trying to weld. If unit is cool and no weld output continues, contact Factory Authorized Service Agent.

6-3. Changing Drive Roll and Wire Inlet Guide

2

4

1

3

Tools Needed:

7/16 in

1Securing Screw

2Inlet Wire Guide

Loosen screw. Slide tip as close to drive rolls as possible without touching. Tighten screw.

3 Drive Roll

The drive roll consists of two different sized grooves. The stamped markings on the end surface of the drive roll refers to the groove on the opposite side of the drive roll. The groove closest to the motor shaft is the proper groove to thread (see Section 4-14).

4 Drive Roll Securing Nut

Turn nut one click to secure drive roll.

Ref. 804 914-A

OM-230 693 Page 29

Page 33
Image 33
Miller Electric OM-230 manual Routine Maintenance, Unit Overload, Changing Drive Roll and Wire Inlet Guide