Miller Electric OM-230 manual Trouble Remedy

Models: OM-230

1 52
Download 52 pages 27.6 Kb
Page 36
Image 36

 

. A complete Parts List is available at www.MillerWelds.com

 

 

Trouble

Remedy

 

 

No wire feed.

Turn Wire Speed control to higher setting (see Section 5-1).

 

 

 

Clear obstruction in gun contact tip or liner (see welding gun Owner’s Manual).

 

 

 

Readjust drive roll pressure (see Section 4-14).

 

 

 

Change to correct size drive rolls (see Section 6-3).

 

 

 

Rethread welding wire (see Section 4-14).

 

 

 

HL.P 002 appears on meters. Thermistor T is detecting an overheating condition. Wait for unit to cool

 

allowing the fan to run. After unit is cool, If HL.P 002 message remains, contact Factory Authorized

 

Service Agent (see Section 6-2).

 

 

 

HL.P 004 appears on meters. Reset message by releasing the trigger or removing stuck wire causing

 

short circuit (see Section 5-2) . If message remains, have Factory Authorized Service Agent check for

 

shorted trigger leads.

 

 

 

HL.P 005 appears on meters. Wire feed malfunction. Check wire feed delivery system.

 

 

 

Check gun trigger and leads. Repair or replace gun if necessary.

 

 

 

Have Factory Authorized Service Agent check main control board.

 

 

OM-230 693 Page 32

Page 36
Image 36
Miller Electric OM-230 manual Trouble Remedy