4-12. Secondary Insulation Protection

1

2

3

5

4

Secondary insulation protection circuitry automatically shuts down the power source output if a potentially hazardous condition exists at the heating device connected to the power source (e.g. insulation has broken down on a heating blanket causing the conductor to come into contact with the workpiece or a heating coil touches the workpiece causing a short in the output circuit).

The supplied ground lead(s) must be connected between the workpiece and power source to provide proper secondary insula- tion protection from a short in the output circuit.

For single output, only one ground lead is required. For dual output , use both ground leads.

1Receptacles

2Plug

To connect plug, align key with key- way, insert end into receptacle, and rotate plug until tight.

3Handle

4Magnet

.The secondary isolation magnet

must be in contact with bare metal (free from rust, paint, grease, etc.).

5 Workpiece

Use handle to place magnet on the workpiece.