Miller Electric ProHeat 35 manual Other end is fitted with a 2-pin type K connector

Models: ProHeat 35

1 72
Download 72 pages 40.46 Kb
Page 26
Image 26

9.The following describes the thermocouple routing from work to power source.

SType K thermocouple wire (two wire) is attached directly to the workpiece using a Thermocouple Attachment Unit (see next section for information on attaching thermocouples).

SThe other end is fitted with a 2-pin type K connector.

SThe 2-pin connector plugs into the 3-pin composite extension cable. The extension cable has a six-channel block of 3-pin female connectors. The pin size locates the position of the 2-pin connector on the extension.

SThe extension cable contains six, 3-wire bundles of shielded cable.

SThe 3-pin male extension cable plugs into the 3-pin female connector on the front of the power source.

1

3

4

2

For temperature control mode, the power source must have (as a minimum) one thermocouple connected to receptacle TC1. If multiple thermocouples are desired, either use individual thermocouple plugs or the thermocouple extension cable.

To connect thermocouples to the power source, proceed as follows:

.Do NOT weld thermocouples to work-

piece while thermocouple cable is con- nected to the power source.

Turn Off power source.

1Power Source

2Thermocouple Receptacles

3Individual Thermocouple Extension Cable

4Multiple Thermocouple Extension Cable

Align plug pin(s) with receptacle socket(s) and push plug into receptacle.

804 320-A

OM-222 166 Page 20

Page 26
Image 26
Miller Electric ProHeat 35 manual Other end is fitted with a 2-pin type K connector