Limit Condition | Additional Information |
|
|
L11: Coolant Overtemp Limit | Check coolant flow and level |
| Clean coolant filters and heat exchanger |
| Increase number of turns |
| Verify appropriate insulation thickness |
|
|
L12: Power Source Overtemp Limit | Check for blocked vents |
| Clean wind tunnel heat sinks |
|
|
L13:Cable Connection | Check for loose/open output connection |
| Verify all output cables are same type |
| Verify receptacle plug connected |
|
|
9-4. Fault Conditions
A fault condition occurs if the system encounters an isolation fault, encounters operating conditions outside operational limits, or if there is a serious
problem with the system. Should a fault condition occur, the output is immediately turned off, the red Fault LED flashes and the Stop | button |
LED flashes. If the active screen on the LCD display is Run Status or Parameters, a message describing the particular fault condition will appear on the
display. If the active screen is Program, press the Run Status | button to display the fault condition. | ||
Pressing the Decrease | button will acknowledge the fault and the red Fault LED will stop flashing and remain on continuously. However, the | ||
Stop | button LED will continue to flash indicating that the process has stopped. |
To obtain additional information regarding the fault condition and suggested solutions to resolve the fault, press the Increase
button, and the
LCD display will indicate possible solutions based on the type of fault condition. In most cases, a fault condition will indicate that service is required.
9-5. Fault Condition Codes
Fault Condition | Additional Information |
|
|
F51: Thermocouple #1 Internal Fault | Service required |
|
|
F52: Themocouple #2 Internal Fault | Service required |
|
|
F53: Thermocouple #3 Internal Fault | Service required |
|
|
F54: Thermocouple #4 Internal Fault | Service required |
|
|
F55: Thermocouple #5 Internal Fault | Service required |
|
|
F56: Thermocouple #6 Internal Fault | Service required |
|
|
F57: CJT Sensor Internal Fault | Service required |
|
|
F58: Output Voltage Fault | Service required |
|
|
F59: Output Current Fault | Service required |
|
|
F60: Temperature Sensor Fault | Check control TC connections |
| Check control TC extension cable |
|
|
F61: Coolant Flow Fault | Check for coolant leak |
| Clean for coolant blockage |
| Check coolant filter and level |
| Check coolant connections |
|
|
F62: Isolation Fault | Check for exposed conductor |
| Clean for moisture on cables |
|
|
F63:Line Voltage Fault | Check line voltage |
|
|
F64: Power Source Overtemp Fault | Verify power source vents and |
| wind tunnel are unobstructed |
|
|
F65: Current Source Fault | Service required |
|
|
F66: Under Frequency Fault | Check for loose or open connections |
| in output cable |
| Decrease number of turns |
| Decrease coil space |
|
|