Typical 5-Segment Custom Program
Custom Program Screen
Mode.......: Custom Program
Segment....: 1
Type.......:>Step
Temperature: 600
Temperature increases to 600 degrees at
Custom Program Screen
Mode.......: Custom Program
Segment....: 2
Type.......: Ramp
Temperature:>1250 Ramp Rate: 600 _/Hr
Controlled heating to 1250 degrees F at a ramp of 600 degrees per hour.
Custom Program Screen
Mode.......: Custom Program
Segment....: 3
Type.......: Soak
Soak Time..:>01:00:00
Soak at 1250 degrees F for a period of 1:00.
Custom Program Screen
Mode.......: Custom Program
Segment....: 4
Type.......:>Ramp
Temperature: 600 Ramp Rate: 600 _/Hr
Controlled cooling to 600 degrees F at a rate of 600 degrees per hour.
Custom Program Screen
Mode.......: Custom Program
Segment....: 5
Type.......: End
Control TC.: 1
End segment ends the heat treat cycle. Controller is programmed to control the process using four thermocouples.
6-4-2. Manual Control
Manual control allows programming of a specific power level for a specific period of time. When this process is selected, the following screen appears on the display: