SECTION 6 − SETUP AND OPERATION

6-1. Safety Equipment

1

2

Wear the

following during

operation:

 

 

 

 

 

 

1

Dry, Insulating Gloves

 

 

2

Safety Glasses With Side

 

 

 

Shields

 

DO NOT wear rings or watches during operation.

sb3.1* 1/94

6-2. System Description

The ProHeat 35 Induction Heating Power Source is designed to function either as an air-cooled system or a liquid-cooled system. Depending on the system type (either air-cooled or liquid-cooled), the power source is automatically configured to operate and provide an output appropriate for the type of connected heating device.

A special identifier, embedded within the extension cable connector, provides the means for the power source to configure itself by recognizing the type of extension cable(s) attached to its output connectors.

Designed to provide a single level of output (up to 35 kW), the ProHeat 35 power source has two panel mounted connectors that are connected in parallel to the power source output. This design allows the system to operate with either a single output extension cable or two output extension cables.

If a single output extension cable is used, a protective plug (provided with the system) MUST be placed on the unused output connector or the system will not operate. If two output extension cables are used, they both MUST be of the same type (either both air-cooled or both liquid-cooled) or the system will not operate (in this case, the protective plug is not used). When two extension cables and heating devices are utilized on the system, the extension cable lengths and heating devices MUST be identical (see Section 4-7).

The ProHeat 35 is intelligent to the point that it will automatically adjust output power levels if internal system operating parameters or internal tempera- tures reach or exceed specific set limits (see Section 9).

6-3. Power Source/System Setup

To view the System Setup screen, simultaneously press the Parameters

on the display:

 

kW

and Program

buttons and the following screen will appear

 

V

A

 

Hz

 

 

 

 

 

 

 

 

 

System Setup Screen

Degree Units: >_F

 

SYSTEM SETUP

Tolerance...: ±25

Backlight: Yes

Input Type..: K TC

Control

Mode: Manual

Power Output: 35 KW

System

Lock: No

To change a setting:

S

Press the Cursor

button to move the cursor to the parameter to be changed

SPress Increase

or Decrease button to select desired set-up feature.

OM-222 166 Page 24

Page 30
Image 30
Miller Electric ProHeat 35 manual Setup and Operation, Safety Equipment, System Description, Power Source/System Setup