4-7. Amperage Adjustment Controls

1 Amperage Adjustment Control

Use control to adjust amperage, and preset amperage on ammeter

1(see Section 4-3). This control may be adjusted while welding.

For remote amperage control, front panel control setting is the maximum amperage available. For example: If front panel control is set to 200 A, the range of the remote amperage control is 5 to 200 A.

For spot welding, use Amperage Adjust control to select from 5–310 amps of peak amperage (see Sec- tion 4-5).

 

2 Amperage Control Switch

 

Use switch to select way of control-

 

ling amperage adjustment.

 

For front panel control, place switch

 

in the PANEL position.

2

For remote control, place switch in

 

REMOTE 14 position, and connect

remote control device (see Section 3-8).

4-8. Output (Contactor) Control Switch

 

 

 

 

Y Weld output terminals are

 

 

 

 

energized when Output

 

 

 

 

(Contactor) switch is On and

 

 

 

 

Power is On.

 

 

 

 

 

 

1

1 Output/Contactor Switch

 

 

 

 

 

Use switch to select way of control-

 

 

 

 

ling unit output.

For front panel control, place switch in ON position.

When On is selected, HF and gas control are disabled.

For remote control, place switch in REMOTE 14 position, and connect remote control device (see Section 3-8).