6-7. Remote 14 Filter Board PC2 Test Point Values (Use With Section 6-2 And Section 6-6)

 

 

 

a) Tolerance – ± 10% unless

 

 

PC2 Voltage Readings

specified

 

 

b) Reference – to circuit common

 

 

 

 

 

 

(lead 42) unless noted

Receptacle

Pin

Value

 

RC1

A

24 volts ac

 

 

B

Contact closure to A completes 24 volts ac contactor control circuit

 

C

Command reference; 0 to +10 volts dc output to remote control

 

D

Remote control circuit common

 

 

E

0 to +10 volts dc input command signal from remote control

 

 

K

Chassis common

 

RC2

1

Command reference; 0 to +10 volts dc output to remote control

 

3

Contact closure to A completes 24 volts ac contactor control circuit

 

4

Remote control circuit common

 

 

5

0 to +10 volts dc input command signal from remote control

 

 

6

24 volts ac

 

RC3

1

Chassis common

TM-353 Page 34

Syncrowave 250

Page 38
Image 38
Miller Electric TM-353E manual RC3