Recorded Inventory Totals don’t

Problem

Corrective action

 

Check the blender’s scale calibration and verify that the batch

 

hopper is not overfilling. If the hopper is overfilling, adjust your

Recorded Inventory Totals don’t

batch size. If this is correct, then you are probably not accounting

match what I’ve actually used

for material scrap or other items in your process.

 

Some error can be introduced by not weighing every batch. Check

 

the Recipe Page.

 

 

Max Hopper Weight Exceeded

Stop the Blender and the Start it again. This causes the blender to

perform an automatic feeder calibration. If this doesn’t fix it, then

Alarm continues to re-occur.

manually perform feeder calibrations and retest.

 

 

 

 

The blender intermittently dumps a batch of material with one or

 

more of the components incomplete.

 

 

Blender occasionally dumps an

Check the recipe information; ensure that both the percentages and

batch size are set properly.

incorrect batch.

 

 

Check the status of the alarm flags & Feeder Setup to ensure that

 

all of the feeders are set to Retry. In addition, if the blender is

 

configured for timed batches then this can cause error.

 

 

 

Check supply hopper ventilation to prevent problem associated

 

with leaky vacuum receiver flappers.

 

 

 

Check the mixer high-level switch sensitivity. When the sensor is

 

covered by material, the indicator lamp on the back of the switch

 

should be lit. To adjust the sensitivity, use the small adjustment

Blender keeps dumping after

screwdriver that was provided with the blender. The adjustment

pot is located on the back of the sensor. Rotate clockwise to

mixer is full.

increase the sensitivity (less material in front of the switch to

 

 

actuate it). Rotate counter clockwise to decrease the sensitivity

 

(more material covering the switch).

 

 

 

Check the mixer high-level sensor connection to the control panel.

 

 

 

Check the mixer high-level switch sensitivity. Fines may have

Blender will not batch with

coated the level switch; it needs readjustment.

 

Check the proximity switch connection.

empty mixer.

Make sure that the recipe is correct.

 

 

 

 

Check batch size.

 

 

 

 