EXTERNAL REMOTE TERMINAL 1

The image can be stored in memory by sending the remote signal through the external remote terminal on the rear panel. When the MEM&PRN(MEMORY & PRINT) function is set to ON, the image will be printed after being stored in memory.

Make out the necessary circuit to use this function by referring to the following.

3

2

1

Circuit inside and pin No.

PRECAUTIONS

2EXTERNAL REMOTE TERMINAL SIGNAL ALLOCATION (STEREO

JACK)

2 3 1

Pin No.

Function

Description

1

GroundEarth

 

 

 

 

2

MEMORY

Memory : When the signal becomes “LOW” from “HIGH”, the

 

 

 

image is stored in memory. (When the signal has

 

 

been “LOW” for 15ms or more, the image is stored

 

 

in memory. See page 51, 52.)

 

 

 

3

BUSY1Refer to the BUSY LEVEL setting of REMOTE SET in SERVICE

 

 

 

MENU. See page 52.

 

 

 

 

To VCP

When the signal from BUSY terminal is received with TTL level, keep the following.

IOL = 2mA or less, IOH = 1mA or less

IOL means the current flowing into the unit at Low output, IOH means the current flowing out of the unit at High output.

Just after completing printing, there is a period that memory signal is not accepted.

From VCP

Plug pin No.

Circuit inside the VCP

DC5V

DTC124EK

10k

22k100

22k2MEMORY

 

DC5V

 

DMC2838

DTC124EK

10k

22k

100

 

22k

3 BUSY

 

 

FEATURES

 

CONNECTIONS

 

PREPARATION

 

PRINTING

 

 

 

 

ADJUSTMENTS

 

SHOOTING

TROUBLE-

 

 

 

 

 

OTHERS

31