2PIN NO. 6 REMOTE TERMINAL

By sending the following remote control codes from pin No.6, the same functions as the wired

 

 

 

1.6 ms (T2)

 

 

 

 

 

 

 

 

 

 

 

remote control unit supplied can be controlled.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01: [ button02: ] button03: } button04: { button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.4 ms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

08: PRINT Q’ty { button09*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(T1)

0A*: MENU button

 

0B*: CLEAR button0C: PRINT Q’ty } button

 

 

 

 

 

 

3.2 ms(T3)

 

 

 

 

 

 

 

 

 

 

 

 

0D*

 

 

0E*: SET button0F*: STOP button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12*: PROGRAM button13*: PRINT button15*: FIELD/FRAME button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16*: COLOR ADJ button 17*: MEMORY button18*: DISPLAY button

 

 

 

 

 

 

 

0.4 ms (T1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1C*: MEMORY PAGE button

 

1D*: MONITOR button

 

 

(The above values are references.)

In case of the codes with * mark, 5 words are sent.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 TIMING CHART

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input signal level

:

 

TTL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input timing

:

 

1 word 38.4 ms (Reference)

 

1

 

1

 

0

 

0

 

1

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

> 0.4 ms

 

 

 

 

 

 

 

1 word

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

(EXAMPLE)

Print code

 

 

 

 

 

 

 

 

 

1.5 ms < T2 < 2 ms

 

 

 

 

 

 

 

 

 

 

2 ms < T3 < 4.2 ms

 

 

 

 

= 13 = 0 1 0 0 1 1

 

 

 

 

 

 

13 ms < T4 < 90 ms

PRECAUTIONS