ADJUSTMENTS & SETTINGS (SERVICE MENU)
RS232C SET
•This menu does not work when selecting THERMAL : ON or MULTI : OFF(PRN SELECT).
BAUD RATE Set the baud rate of•Select “A” for normal setting. Depending on the connected equipment, select “B” or “C”.
RS232C SET |
|
BAUD RATE | 1200/2400/4800/9600 |
COMMAND TYPE | A/B/C |
RESPONSE | OFF/ON |
ERR RES OK | NOR/ILL/INV/ALL |
NO DSR | OFF/ON |
|
|
RESPONSE | Selects whether this unit sends |
| computer or not. |
OFF | Does not send response. |
ON | Sends normal response. |
ERR RES OK | Selects the response code when an error occurs. |
NOR | Sends the regular response. |
ILL | Sends “job end” even if ILLEGAL error occurs. |
INV | Sends “job end” even if INVALID error occurs. |
ALL | Sends “job end” when any error occurs. |
NO DSR | Sets to use 232C, DSR and DTR. |
| Sets “NO DSR” according to the connecting device. |
OFF | Uses NO DSR. |
ON | Does not use NO DSR. |
REMOTE SET Remote signal setting display
BUSY LEVEL | Selects the level of BUSY signal from the remote terminals 1 and 2 |
| on the rear panel. |
LOW | The VCP cannot accept the remote input signal when the signal is |
| “LOW”. |
HIGH | The VCP cannot accept the remote input signal when the signal is |
| “HIGH”. |
BUSY 1,2 SELECT Selects when the BUSY signal is outputted from the remote terminals 1 and 2 on the rear panel.
PRINTING Outputs BUSY signal during printing.MECHA ERR Outputs BUSY signal when a mechanical error occurs in this unit or IC chip is not installed. BUSY signal is also outputted when the printing mechanism is pulled out or the menu is displayed on the monitor.
MEDIA ERR Outputs BUSY signal when an error for paper or ink sheet occurs. MEMORY STOP Outputs BUSY signal when MEMORY button is not functioning.
STROBE 1V After outputting BUSY signal, memory is taken in by waiting to 1 vertical period.
STROBE 2V After outputting BUSY signal, memory is taken in by waiting to 2 vertical periods.
REMAINING Outputs BUSY signal while the remains of ink sheet becomes the value set in REMAINING Q’ty.
•When either STROBE 1V or STROBE 2V is set to OFF, the other is available for setting.
REMOTE SET |
|
BUSY LEVEL | LOW/HIGH |
BUSY1,2 SELECT |
|
PRINTING | OFF/1/2/1&2 |
MECHA ERR | OFF/1/2/1&2 |
MEDIA ERR | OFF/1/2/1&2 |
MEMORY STOP | OFF/1/2/1&2 |
STROBE 1V | OFF/1/2/1&2 |
STROBE 2V | OFF/1/2/1&2 |
REMAINING | OFF/1/2/1&2 |
|
|
52