Page 42
Image 42

U-11Remote control (continued)

Carry out as necessary

5)Read command

The computer sends the command without datacode to the monitor.

After receiving this command, the monitor returns the command with datacode including the current status to the computer. Example: When the computer asks the power status of the monitor, and the status of the monitor is powered-on.

Command from computer

 

 

Command from monitor

 

Detail of command

30 30 76 50 0D

‘0’‘0’‘v’‘P’[enter]

 

 

 

 

 

Ask about the power status of the monitor.

 

 

 

 

30 30 76 50 31 0D

‘0’‘0’‘v’‘P’‘1’[enter]

Monitor is powered-on.

Structure of the Read-command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASCII

 

HEX

 

 

 

 

 

 

Function

 

Data (Receive)

Function

 

Data (Receive)

 

POWER

 

ON

 

 

vP

 

1

76 50

 

31

 

 

OFF (stand by)

 

 

vP

 

0

76 50

 

30

 

 

 

 

 

 

 

 

 

 

RGB-1 (HDMI)

 

 

vI

 

r1

76 49

 

72 31

 

 

 

RGB-2 (DVI-D)

 

 

vI

 

r2

76 49

 

72 32

 

 

 

RGB-3 (D-SUB)

 

 

vI

 

r3

76 49

 

72 33

 

 

 

RGB-4 (BNC)

 

 

vI

 

r4

76 49

 

72 34

 

Input

 

RGB-5 (CAT5)

 

 

vI

 

r5

76 49

 

72 35

 

 

 

RGB-6 (DISPLAY PORT)

vI

 

r6

76 49

 

72 36

 

 

 

Video

 

 

vI

 

v1

76 49

 

76 31

 

 

 

DVD/HD

 

 

vI

 

v2

76 49

 

76 32

 

 

 

S-VIDEO

 

 

vI

 

v3

76 49

 

76 33

 

 

 

Around the main

Resolution

tc1

 

(ex.) +25

74 63 31

 

2B 20 32 35

 

Internal

 

board

1˚C

 

 

 

 

 

 

 

 

 

 

 

temperature

 

Around the power

Resolution

tc2

 

(ex.) +31

74 63 32

 

2B 20 33 31

 

 

 

supply

1˚C

 

 

 

 

 

 

 

 

 

 

 

 

LAN Remote control

By connecting the monitor and the computer using a network device such as a LAN hub as shown in Section P-7 and making the network settings using the OSD menu and RS-232C communication control, you can perform remote control using the same commands as those for RS-232C.

1.Setting procedure

(1)Set the following network parameters using the OSD menu. (See page 47.)

• ON/OFF, IP address, subnet mask, gateway mask setting, and default gateway of DHCP client

(2)Send the same control command as that for RS-232C via TCP/IP socket communication.

(3)Check the status sent from the monitor. When it is received successfully, the setting is completed.