AT Commands MIM-A01

Appendix

 

 

 

 

 

 

 

Command

Description

 

&Z

Store telephone number (up to 30 digits) to location 'n' (0-3)

 

%E

Auto-retrain control

 

%G

Rate renegotiation

 

-C

Generate data mode calling tone

 

+ES

Error control selection

 

+MS

Modulation selection

 

*NC

CallerID settings

 

+VCID

Country code setting

 

@D

Accept a new firmware image to flash

Tab. 8-23:Overview of AT Commands (2)

8.2.2AT Command Descriptions

This chapter describes the most important AT commands of the modem. The values marked with an asterisk (*) are the default values.

+TFORMAT - Sets the data format

Sets the data format of the serial interface. +TFORMAT="Dataformat"

Dataformat: DatabitsParityStopbits

Databits:

8,

7

Parity:

N

(none), O (odd), E (even), X (auto-detection, default)

Stopbits:

1,

2

+TBAUD - Set the baudrate

Sets the baud rate of the serial interface. +TBAUD="Baudrate"

Baudrate: AUTO (default), 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400

&K - Select Serial Port Flow Control

This command specifies the DTE-to-modem flow control. Software flow control uses the charac- ters XOFF (13h) and XON (11h) to stop and start data transmission, respectively, both to and from the DTE. Bidirectional hardware flow control uses RTS/CTS to stop and start data from the modem

&K0

Disables flow control

&K3*

Bi-directional hardware flow control - RTS/CTS

&K4

XON/XOFF software flow control

&D - DTR (Data Terminal Ready) Option

This command controls how the modem responds to DTR. After toggling DTR, the host should wait 200 ms before modifying the UART registers or sending a new command to the modem. This is done because the modem does not send an ‘OK’ message to indicate it has performed the requested function.

&D0

The modem ignores DTR.

&D1

Themodemswitchesfromdatatocommandmodewhenanon-to-offtransitionofDTRoccurs.

&D2*

An on-to-off transition of DTR causes the modem to go on-hook (hang up). While DTR

 

is off, auto-answer is disabled.

&D3

An on-to-off transition of DTR reinitializes the modem. The reinitialize procedure performs the

 

same function as a power-up reset, except that the UART registers are not reconfigured.

8 - 10

MITSUBISHI ELECTRIC

Page 44
Image 44
Mitsubishi Electronics MIM-A01, MIM-G01 AT Command Descriptions, +TFORMAT Sets the data format, +TBAUD Set the baudrate

MIM-G01, MIM-A01 specifications

Mitsubishi Electronics has long been a frontrunner in the realm of advanced technology, particularly in the development and optimization of automation solutions. Two of their standout offerings in the field of air conditioning technology are the MIM-A01 and MIM-G01 systems, which cater to both residential and commercial applications.

The MIM-A01 is an indoor unit featuring a sleek design that blends seamlessly with modern interior aesthetics. This unit is engineered for energy efficiency, boasting an impressive seasonal energy efficiency ratio (SEER) that significantly reduces electricity consumption. One of its key features is the V-Flow design technology, which allows for enhanced airflow distribution, ensuring that every corner of the room receives adequate cooling or heating. The MIM-A01 also comes with advanced filtration systems, including a high-performance filter that captures dust and allergens, promoting a healthier indoor environment.

On the other hand, the MIM-G01 represents Mitsubishi's commitment to high-quality outdoor units. This model is known for its compact size and robust design, making it suitable for a variety of installation spaces. With its advanced inverter technology, the MIM-G01 can adjust its cooling or heating output according to the changing conditions, thereby optimizing energy usage. One of its hallmark technologies is the Hyper Heating feature, which allows the unit to maintain its performance even at extremely low outdoor temperatures, making it ideal for colder climates.

Both units share a common thread of smart technology integration. They are equipped with wireless control capabilities, allowing users to adjust settings remotely via smartphone apps or smart home systems. This feature not only enhances user convenience but also facilitates better energy management by allowing users to monitor and control energy use from anywhere.

In summary, the Mitsubishi Electronics MIM-A01 and MIM-G01 systems epitomize modern air conditioning technology with their focus on energy efficiency, innovative airflow design, and advanced smart features. Whether for a small residential space or a larger commercial application, these units align with the evolving demands of energy-conscious consumers while delivering optimal performance and comfort. Their commitment to quality and advanced technology solidifies Mitsubishi's position as a leader in the HVAC industry.