Mitsubishi Electronics MSZ-FA25VA, MSZ-FA35VA service manual Check of auto front panel

Models: MSZ-FA25VA MSZ-FA35VA

1 40
Download 40 pages 15.69 Kb
Page 28
Image 28

Indoor unit and outdoor unit do not operate.

H Check of auto front panel

Turn the remote controller ON.

Does the front panel automatically open? (Does it start to move?)

Yes

No

Is the connector of the front panel driving motor unit or the indoor electric control P.C. board unplugged?

Yes

Plug in the connector and check from the start again.

No

Is the resistance value between

No

 

terminals of the front panel driving

 

motor unit normal?

 

Is the front panel held 10mm or more upper than the level line of the nozzle top?

Yes

Front panel is normal.

No

Replace the front panel driving motor unit.

Yes

Replace the indoor electric control P.C. board.

10 mm or more

Z-Z side view

Replace the front panel driving motor unit.

28

Page 28
Image 28
Mitsubishi Electronics MSZ-FA25VA, MSZ-FA35VA Check of auto front panel, Indoor unit and outdoor unit do not operate