| OPERATING PROCEDURE | PHOTOS |
4. Removing the horizontal vane motor unit | Photo 6 | |
(1) | Remove the horizontal vane and the panel. (Refer to 1.) | Screw of the horizontal |
(2) | Remove the screws of the horizontal vane motor unit, | vane motor unit |
| and pull out the horizontal vane motor unit. (See Photo 6.) |
|
(3) | Disconnect the connector from the horizontal vane motor |
|
| unit. |
|
5. Removing the vertical vane motor unit | Photo 7 |
(1)Remove the horizontal vane, the panel (Refer to 1.) and the corner box.
(2)Pull out the drain hose from the nozzle assembly, and remove the nozzle assembly. (See Photo 5.)
(3) Remove the crank of the vertical vane motor unit from the arm of the vertical vane.(See Photo 7.)
(4) Remove the screws of the vertical vane motor unit, and pull
the vertical vane motor unit. (See Photo 7.)
Arm
Crank of the vertical vane motor unit
Screws of the vertical vane motor unit
6. Removing the indoor fan motor and the line flow | Photo 8 | Motor band | |
fan | |||
|
|
(1)Remove the horizontal vane, the panel (Refer to 1.) and the corner box.
(2)Remove the switch holder and the electrical box. (Refer to 3.)
(3)Pull out the drain hose from the nozzle assembly, and remove the nozzle assembly.
(4)Remove the screws fixing the motor bed. (See Photo 8.)
(5) Loosen the screw fixing the line flow fan. (See Photo 9.) |
| |
(6) | Remove the motor bed together with fan motor and motor |
|
| band. |
|
(7) | Release the hooks of the motor band, and remove the |
|
| motor band then pull out the indoor fan motor. | Screws of |
(8) | Remove the screws fixing the left side of the heat | |
| exchanger. (See Photo 10.) | the motor |
(9) | Lift the heat exchanger, and pull out the line flow fan to the | bed |
| Photo 10 | |
|
| |
| Photo 9 |
|
|
| Screws of the |
| Screw of | left side of the |
| the line | heat exchanger |
| flow fan |
|
33