6. How to remove and install PLASMA DEODORIZING / AIR PURIFYING filter units
If PLASMA/WASH lamp on the indoor unit blinks, clean the filters as soon as possible. The lamp will start blinking when accumulated operating time exceeds 330 hours.
<Remove>
(1)Switch the indoor unit OFF with the remote controller and disconnect the power supply plug and/ or turn OFF the breaker.
NOTE: Otherwise, you may get injured since PLASMA DEODORIZING/AIR PURIFYING filter units are charged with high voltage.
(2)Hold the knobs on both sides of the front panel and lift the panel up until its level.
(3)Remove the
(4)Remove PLASMA DEODORIZING/AIR PURIFYING filter units. (See Figure 2.)
Figure 1.
Figure 2.
<Install>
Install PLASMA DEODORIZING/AIR PURIFYING filter units by following the removal procedure in reverse.
(1)Insert the top of PLASMA DEODORIZING/AIR PURIFYING filter units into the aperture in the plasma element holder.
(See Figure 3.)
(2)Push in PLASMA DEODORIZING/AIR PURIFYING filter units until they click into place.
•The front panel does not close if PLASMA DEODORIZING/AIR PURIFYING filter units are not installed properly.
(3)Install the
(4)Connect the power supply plug and/ or turn ON the breaker.
(5)Press WASH reset switch. A short “beep” is heard and the blinks of PLASMA/WASH lamp will be cancelled. Make sure PLASMA/ WASH lamp is not blinking at the start of operation next time.
(See Figure 4.)
(6)Hold both sides of the front panel and close the front panel.
(7)Press the 3 positions on the front panel as indicated by the arrows.(See Figure 5.)
NOTE:
Install PLASMA DEODORIZING/AIR PURIFYING filter units only when they are completely dry. If the filter unit remains wet, PLASMA/WASH lamp may blink and the plasma function may be disabled.(When PLASMA DEODORIZING/AIR PURIFYING filter units are cleaned.)
Figure 3.
Figure 4.
Plasma element holder
E.O.
SW
WASH
reset
Figure 5.
12