How to release “AUT O RESTART FUNCTION” 1Turn off the main power for the unit.
2Solder the Jumper wire to JR07 on the indoor electronic control P.C. board. (Refer to
CN130
IC156
JR07
CN212 CN151 CN1T2 CN1T1 CN112CN1R1 CN211
NOTE:
•The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the remote controller.
•If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is cancelled.
•If the unit has been off with the remote controller before power failure, the auto restart function does not works as the power button of the remote controller is off.
•To prevent breaker off due to the rush of starting current, systematize other home appliance not to turn on at the same time.
•When some air conditioners are connected to the same supply system, if they are operated before power failure, the starting current of all the compressors may flow simultaneously at restart.
Therefore, the special
8-4. Remote controller
Be sure to set the slide switch inside the remote controller to an appropriate position in accordance with the installed position of the indoor unit. If the switch is not set correctly, the air conditioner may not function properly.
Side swich
Where is the indoor unit installed in your room?
Area | Left | Center | Right |
Position of
the slide
switch
Display on the remote controller
Installed at left , if the | Installed at right , if the |
distance is not more | distance is not more |
than 50 cm. | than 50 cm. |
(Left) | (Center) | (Right) |
Is the indoor unit in- stalled at right, left or center?
NOTE:If the indoor unit is installed more than 50 cm away from the side walls, cabinets or other nearby objects, set the slide switch to the “center” position.
10