Lighted · Flashing of AREA lamp(left-hand side lamp) indicates abnormality.

Blinking

Not lighted

NOTE : Before taking measures, make sure that the symptom reappears for accurate troubleshooting. Self check table

No.

Abnormal

Operation indicator lamp

Symptom

Detection method

Check point

 

point

 

 

 

 

 

Indoor

Left lamp of AREA lamp flashes.

Indoor unit

When it cannot properly read data in the

 

 

4-time flash

 

 

and outdoor

• Replace the indoor electronic

1

control

 

nonvolatile memory of the indoor electronic

 

unit do not

control P.C. board.

 

system

 

control P.C. board.

 

 

operate.

 

 

 

2.5-second OFF

 

 

 

 

 

 

 

Lighted

· Flashing of All lamps indicate abnormality.

Blinking

Not lighted

No.

Abnormal

Operation indicator lamp

Symptom

Detection method

Check point

 

point

 

 

 

 

 

Attachment

All lamps flash at the same time.

Indoor unit

 

 

 

0.5-second ON

When the electricity is not conducted to the

• Refer to 9-6.E"Check of

 

of the

and outdoor

1

installation of the horizontal

 

horizontal

 

unit do not

interlock switch (Fan) of the horizontal vane.

vane".

 

vane

 

operate.

 

 

0.5-second OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

Lighted

· Flashing of AREA lamp(both lamps) indicates abnormality.

Blinking

· POWER lamp is lighted.

Not lighted

No.

Abnormal

Operation indicator lamp

Symptom

Detection method

Check point

 

point

 

 

 

 

 

MXZ type

Both lamps flash

Outdoor unit

When the operation mode of the each indoor

• Unify the operation mode.

 

Operation

 

operates but

unit is differently set to COOL(includes DRY)

1

 

Refer to service manual

 

indoor unit

and HEAT at the same time, the operation

mode

 

 

OB377.

 

2.5-second OFF

does not

mode of the indoor unit that has operated at

 

setting

 

 

 

 

 

operate.

first has the priority.

 

Lighted · Flashing of PLASMA/WASH lamp indicates abnormality.

Blinking

Not lighted

No.

Abnormal

Operation indicator lamp

Symptom

Detection method

Check point

 

point

 

 

 

 

 

PLASMA

PLASMA/WASH lamp flashes.

Indoor unit

 

 

 

DEODORIZING/

When PLASMA DEODORIZING power or

 

 

PLASMA

2-time flash

and outdoor

• Replace the indoor electronic

1

 

PLASMA AIR PURIFYING power can not be

AIR

 

unit do not

control P.C. board.

 

PURIFYING

 

operate.

turned OFF.

 

 

power control

2.5-second OFF

 

 

 

NOTE : When the indoor unit has started operation and the above detection method has detected an abnormality (the first detection after the power ON), the indoor electronic control P.C. board turns OFF the indoor fan motor with OPERATION INDICATOR lamp flashing.