9-6. Troubleshooting flow

When POWER lamp flashes 3-time.

Indoor fan does not operate.

A Check of indoor fan motor

The indoor fan motor error has occurred, and the indoor fan doesn't operate.

Turn OFF the power supply.

Insert a stick such as a screw driver into the air outlet, and check if there is any catch in the rotation of the line flow fan.

Is there any foreign matter that interferes the rotation of the line flow fan?

Yes

Adjust the line flow fan and remove the foreign matter.

No

Pay careful attention to the high voltage on the fan motor connector CN211.

w

Turn ON the power supply, wait 5 seconds or more, and then press EMERGENCY OPERATION switch.

Measure the supply voltage as follows within 12 seconds after EMERGENCY OPERATION switch is pressed.

If more than 12 seconds passes by, turn OFF the power supply and turn ON it again, then measure the voltage.

1.Measure the voltage between CN211 1(+) and 3(-). 2.Measure the voltage between CN211 5(+) and 3(-).

wIf 12 seconds or more passes after EMERGENCY OPERATION switch is pressed, the voltage mentioned above 2 goes 0V DC although the indoor electric control P.C. board is normal.

Is there 311V DC between

 

 

 

CN211 1 (+) and 3 (-), and does

 

 

 

the voltage between CN211 5(+)

Yes

 

and 3(-) rise to the range of 3 to 6V

 

 

Replace the indoor fan motor.

 

DC within 12 seconds after

 

 

 

 

 

 

EMERGENCY OPERATION switch

 

 

 

is pressed?

 

 

 

 

No

 

 

 

 

 

 

 

 

 

 

 

 

Indoor electronic control P.C. board

CN211

Replace the indoor electronic control P.C. board.

The indoor fan motor error has occurred, and the indoor fan repeats "12-second ON and 30-second OFF" 3 times, and then stops.

Measure the voltage between CN211

 

Is it unchanged holding

Changed

 

 

Replace the indoor electronic control P.C. board.

6(+) and 3(-) while the fan

 

0V DC or 15V DC?

 

 

 

 

motor is rotating.

 

 

 

 

 

 

 

 

 

Unchanged

Replace the indoor fan motor.