9-5.  Trouble criterion of main parts
MSZ-FA25VA  - E1
MSZ-FA35VA  - E1
Part name
Room temperature thermistor(RT11)
Indoor coil thermistor (RT12(MAIN), RT13(SUB))
Indoor fan motor(MF)
| Check method and criterion | Figure | 
Measure the resistance with a tester. (Part temperature 10˚C ~ 30˚C)
| Normal | Abnormal | 
| 8 k" ~ 20 k" | Open or  | 
| Check  | 
 | 
Horizontal vane motor(MV1)
Measure the resistance between the terminals with a tester. (Part temperature 10°C ~ 30°C)
| Color of the lead wire | Normal | Abnormal | 
| 235 " ~ 255 " | Open or  | 
RED
ROTOR
YLW
BRN 
ORN GRN
Vertical vane motor(MV2)
Measure the resistance between the terminals with a tester. (Part temperature 10°C ~ 30°C)
| Color of the lead wire | Normal | Abnormal | 
| 282 " ~ 306 " | Open or  | 
RED
ROTOR
YLW
BRN 
ORN GRN
Front panel driving motor (MP)
Measure the resistance between the terminals with a tester. (Part temperature 10°C ~ 30°C)
| Color of the lead wire | Normal | Abnormal | 
| 94 " ~ 102 " | Open or  | 
Turn the power 
(Part temperature 10 ~ 40°C)
| 
 | w The aluminum block | 
| Aluminum block  | part is covered with | 
| 
 | black vinyl tape. | 
RED
ROTOR
YLW
BRN 
ORN GRN
| 
 | Connector | 
 | 
 | Black | 
 | |||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | vinyl tape | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | Normal range | 
 | Abnormal | |||||
| connector terminals | 
 | |||||||
| 
 | 
 | 
 | 
 | 
 | ||||
| 
 | 1.874 ~ 3.387V DC | Below 1.874 or above 3.387V DC | ||||||
| 1(+) -  | 
 | 1.010 ~ 1.420V DC | Below 1.010 or above 1.420V DC | |||||
NOTE: Pay attention to static electricity.
| PLASMA DEODORIZING/ | 
 | 
| PLASMA AIR PURIFYING | Check  | 
| power | 
 | 
20