PEH-8,10MYA-EU
(SPECIAL WIRING : ANTI SHORT CYCLE TIMER., PROTECT FOR COOL AIR BLOW.
)
Power supply, | 3Phase | TB1 |
| ||
380 | 415Volt, | 50Hertz |
| ||
L1 |
| ||||
|
|
|
| ||
|
|
| L2 | RED | |
|
|
|
| ||
|
|
| L3 |
| |
CIRCUIT BREAKER |
| BLUE | |||
(FIELD SUPPLY) 100A | N | ||||
|
PE
52C | RED |
|
|
RED |
|
| |
WHITE | WHITE |
| |
BLACK | BLACK |
| |
| RED |
| 51F2 |
|
|
| |
F3(3.15A) | WHITE |
| |
| BLACK |
| |
HZ2 |
|
|
|
49C |
|
|
|
X3 | X1 | X2 | T1 |
52C |
|
|
|
51F2 |
|
| C7 |
|
|
| 3 |
|
|
| 26 |
63H |
|
| D2 |
51C
X1 | 1C4 RED |
2WHITE
3 | MF2 |
BLACK |
1RED
2WHITE
3 | MF3 |
BLACK |
C5 | MF3 is only | |
X1 | ||
|
TB4 (In case of
16
GRAY
MC
|
|
| C7 | X3 |
51C |
| 21 | 1 |
|
T1 |
| 17 | ||
CZ2 | S4 | C6 | ||
|
| CZ2 HZ2 | ||
|
| X3 | 1 |
|
CH |
| 26 | X2 | |
|
| D1 | ||
30 |
|
| ||
CZ | CR2 |
| C6 |
|
|
|
| 3 |
|
| 52C | 14 |
|
| |
30 |
| X1 X2 |
CZ |
|
Power supply, 3Phase | TB2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
380 415Volt, 50Hertz |
|
| 52F |
|
| 51F | 1C1 RED |
|
| RED C21 |
|
|
|
| ||||
L1 | RED |
|
|
|
|
|
|
|
|
| ||||||||
|
| L2 | WHITE |
|
|
|
| 2 | WHITE | MF1 | WHITE | 2 |
|
|
|
| ||
|
| L3 | BLACK |
|
|
|
| 3 | BLUE | BLUE | 3 |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |||||||
CIRCUIT BREAKER |
| RED | F3(3.15A) |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
(FIELD SUPPLY) 15A | N |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| BLUE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| 51F1 |
|
|
|
| GRAY | TB4 | 1 |
|
| 52F |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| C1 |
|
|
|
|
|
|
| SWITCH BOX |
| CZ1 | HZ1 |
| ||
|
| PE |
| 4 |
|
|
|
|
|
|
| (FIELD SUPPLY) |
|
| ||||
|
|
|
| 49F | OUT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C1 |
| 16 |
| F2 |
|
|
|
|
|
| TM |
|
| |
|
|
|
| DOOR |
|
| SW1 |
|
|
|
|
| ||||||
|
|
|
| 5 |
|
| (3.15A) |
|
|
|
| (3MIN) |
|
| ||||
|
|
|
|
|
|
| 16 |
|
| COOL |
| HEAT |
|
| TB3 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
| 15 | 13 |
| ||||
|
|
|
| C3 |
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 1 |
|
| X3 |
|
|
|
|
|
|
|
| 15 | 13 | OUTDOOR |
|
|
|
| 26L | HZ1 |
|
|
| C | H |
|
|
|
| ||||
|
|
|
|
|
| Tr |
|
| SW2 |
|
| |||||||
|
|
|
| C3 |
|
| 17 |
|
| 23 |
|
|
|
| ||||
|
|
|
| FZ |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
| 3 |
|
|
|
|
| WA |
|
| CZ2 HZ2 |
| ||||
|
|
|
|
|
|
| 17 | AC | AC |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| TM |
|
|
| |||
|
|
|
|
|
|
|
| 220 | 24V |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
| 30FZ |
|
| CR1 240V |
| TB4 | 2 | 3 | 4 |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| 52F |
|
| CZ1 | HZ1 |
|
| 14 |
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
| 30 |
|
|
|
|
|
|
|
|
| FZ |
|
|
|
|
|
|
|
| FZ |
|
|
|
|
| GRAY | 5 |
|
| 14 |
|
| ||
|
|
| BLUE |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Attach the accessory
|
|
|
|
|
|
|
|
|
|
| Compressor motor |
|
|
| Fan motor (indoor) |
|
|
| Fan motor (outdoor) |
|
|
| Contactor (compressor) |
|
|
| Contactor (fan I/D) |
TB1 | 5 |
| Terminal block |
|
|
| Crankcase heater |
F1 | 3 |
| Fuse (3.15A) |
|
|
| Transformer |
49F |
|
| Internal thermostat(indoor fan) |
|
|
| Internal thermostat(compressor) |
|
|
| Over current relay (compressor) |
|
|
| Over current relay(fanI/D,O/D) |
|
|
| |
26L |
|
| Thermostat (freeze protection) |
|
|
| Thermostat (defrost) |
|
|
|
|
|
|
| Auxiliary relay (fan) |
CZ1, 2 | Auxiliary relay (compressor) | ||
HZ1, 2 | Auxiliary relay | ||
30CZ, FZ | Auxiliary relay (check) | ||
|
|
| Contactor (fan O/D) |
|
|
| Auxiliary relay (defrost) |
|
|
| Switch (operation mode) |
|
|
| Switch (on) |
|
|
| Thermostat (room temp.) |
C1~7 | Connector (C5 is | ||
|
|
| Timer (defrost) |
CR1, 2 | Surge killer | ||
|
|
| Timer (Anti short cycle) |
1C1 |
| C2 | 1 | Remove |
|
| |||
2 |
|
| 2 | 1 |
3 | MF1 |
| 3 | 2 |
|
| 3 | ||
|
|
|
|
This circuit diagram shows connections. (If the external static Pressure is less than 30 Pa, change to connections.)
Note:1.The dotted lines show field wiring.
2.The figure in the parentheses show field supply parts. 3.Color of earth wire is yellow and green twisting. 4.Not specified color of wire is brown.
5.When PAC-204RC is used, Timer(TM)is unneccessary.
6.Specification subject to change without notice.
Caution,
1.To protect each Fan motor and Compressor from abnormal current, Over current relays <51C>, <51F1,2> are installed. Therefore, do not change factory set value of Over current relays.
Option controller connection.
Symbol | No. | Function | ||
terminal no. | ||||
|
|
| ||
| 1 | Power (Active) | 24VAC(L) | |
| 2 | Cooling or Heating | COMP | |
TB4 |
| operation |
| |
3 | Reversing valve | 4WV | ||
| ||||
|
| for Heating operation |
| |
| 4 | Fan operation | FAN HI | |
| 5 | Power (Neutral) | 24VAC(N) |
- 66 -