PEH-5,7,8MYA-EU

Cooling

VOLT

ITEM

 

PEH-5MYA-EU

PEH-7MYA-EU

PEH-8MYA-EU

 

PUH-5MYE-EU

PUH-7MYC1-EU

PUH-8MYC1-EU

PUH-8MYE-EU

 

 

 

 

TOTAL INPUT

kW

5.5

7.2

7.8

7.9

 

TOTAL RUN CURRENT

A

9.5

14.6

14.2

14.7

PEH-7

POWER FACTOR

%

80

-

76

75

START CURRENT

A

69

74

83

83

240V

 

 

 

 

 

 

 

COMPRESSOR INPUT

kW

4.7

6.0

6.8

6.77

PEH-

RUN CURRENT

A

8.1

10.7

12.3

12.3

8 20

INDOOR FAN INPUT

kW

0.54

0.8

0.6

0.6

415V

RUN CURRENT

A

0.9

3.2

1.2

1.2

 

OUTDOOR FAN INPUT

kW

0.25

0.4

0.4

0.53

 

RUN CURRENT

A

0.5

0.7

0.7

1.2

 

 

 

 

 

 

 

 

TOTAL INPUT

kW

5.5

7.2

7.8

7.9

 

TOTAL RUN CURRENT

A

10.4

15.9

15.5

16.0

PEH-7

POWER FACTOR

%

80

-

76

75

220V

START CURRENT

A

69

81

91

91

 

 

 

 

 

 

 

PEH-

COMPRESSOR INPUT

kW

4.7

6.0

6.8

6.77

RUN CURRENT

A

8.85

11.6

13.4

13.4

8 20

INDOOR FAN INPUT

kW

0.54

0.8

0.6

0.6

380V

 

 

 

 

 

 

RUN CURRENT

A

1.0

3.5

1.3

1.3

 

 

OUTDOOR FAN INPUT

kW

0.25

0.4

0.4

0.53

 

RUN CURRENT

A

0.55

0.8

0.8

1.3

Heating

VOLT

ITEM

 

PEH-5MYA-EU

PEH-7MYA-EU

PEH-8MYA-EU

 

 

 

 

 

 

PUH-5MYE-EU

PUH-7MYC1-EU

PUH-8MYC1-EU

PUH-8MYE-EU

 

 

 

 

TOTAL INPUT

kW

4.5

6.3

6.5

6.6

 

TOTAL RUN CURRENT

A

8.5

13.6

12.4

12.9

PEH-7

POWER FACTOR

%

73

-

73

71

START CURRENT

A

69

74

83

83

240V

 

 

 

 

 

 

 

COMPRESSOR INPUT

kW

3.7

5.1

5.5

5.47

PEH-

RUN CURRENT

A

7.1

9.7

10.5

10.5

8 20

INDOOR FAN INPUT

kW

0.54

0.8

0.6

0.6

415V

RUN CURRENT

A

0.9

3.2

1.2

1.2

 

OUTDOOR FAN INPUT

kW

0.25

0.4

0.4

0.53

 

RUN CURRENT

A

0.5

0.7

0.7

1.2

 

 

 

 

 

 

 

 

TOTAL INPUT

kW

4.5

6.3

6.5

6.6

 

TOTAL RUN CURRENT

A

9.2

14.9

13.6

14.1

PEH-7

POWER FACTOR

%

74

-

73

71

220V

START CURRENT

A

69

81

91

91

 

 

 

 

 

 

 

PEH-

COMPRESSOR INPUT

kW

3.7

5.1

5.5

5.47

RUN CURRENT

A

7.75

10.6

11.5

11.5

8 20

INDOOR FAN INPUT

kW

0.54

0.8

0.6

0.6

380V

 

 

 

 

 

 

RUN CURRENT

A

1.0

3.5

1.3

1.3

 

 

OUTDOOR FAN INPUT

kW

0.25

0.4

0.4

0.53

 

RUN CURRENT

A

0.55

0.8

0.8

1.3

- 12 -

Page 13
Image 13
Mitsubishi Electronics PE-20MYC, PE-8MYC, PE-15MYC, PE-10MYC, PEH-10MYA, PE-7MYC, PEH-8MYA, PEH-7MYA PEH-5,7,8MYA-EU, Heating