S e t t i n g D I P S w i t c h e s
To change the DIP switch settings, move the switches to the desired position and then turn on the printer.
If you select Software Controlled, the parameters in Packet F will override the communication settings. Software Controlled uses the last sent Packet F settings or the defaults. Turning on the printer activates the DIP switch settings. Make sure the DIP switch settings match the printer’s setup for ribbon or supply type.
Upper DIP Switches |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Baud Rate | ON | ON | OFF |
|
|
|
|
|
38400 |
|
|
|
|
| |||
19200 | ON | OFF | ON |
|
|
|
|
|
9600 | ON | OFF | OFF |
|
|
|
|
|
4800 | OFF | ON | ON |
|
|
|
|
|
2400 | OFF | ON | OFF |
|
|
|
|
|
1200 | OFF | OFF | ON |
|
|
|
|
|
Software Control | OFF | OFF | OFF |
|
|
|
|
|
Data Bits |
|
|
|
|
|
|
|
|
7 Data Bits |
|
|
| ON |
|
|
|
|
8 Data Bits |
|
|
| OFF |
|
|
|
|
Stop Bits |
|
|
|
|
|
|
|
|
2 Stop Bits |
|
|
|
| ON |
|
|
|
1 Stop Bit |
|
|
|
| OFF |
|
|
|
Parity |
|
|
|
|
| ON | OFF |
|
Even |
|
|
|
|
|
| ||
Odd |
|
|
|
|
| OFF | ON |
|
None |
|
|
|
|
| OFF | OFF |
|
Parallel Port |
|
|
|
|
|
|
|
|
Centronics Mode |
|
|
|
|
|
|
| OFF |
|
|
|
|
|
|
| ON |
Communication settings at the printer must match those at the host. Make sure your host is capable of communicating at the speed you select for the printer.
Getting Started