Monarch 9800 manual S e t t i n g D I P S w i t c h e s

Models: 9800

1 64
Download 64 pages 51.61 Kb
Page 10
Image 10
S e t t i n g D I P S w i t c h e s

S e t t i n g D I P S w i t c h e s

To change the DIP switch settings, move the switches to the desired position and then turn on the printer.

If you select Software Controlled, the parameters in Packet F will override the communication settings. Software Controlled uses the last sent Packet F settings or the defaults. Turning on the printer activates the DIP switch settings. Make sure the DIP switch settings match the printer’s setup for ribbon or supply type.

Upper DIP Switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

Baud Rate

ON

ON

OFF

 

 

 

 

 

38400

 

 

 

 

 

19200

ON

OFF

ON

 

 

 

 

 

9600

ON

OFF

OFF

 

 

 

 

 

4800

OFF

ON

ON

 

 

 

 

 

2400

OFF

ON

OFF

 

 

 

 

 

1200

OFF

OFF

ON

 

 

 

 

 

Software Control

OFF

OFF

OFF

 

 

 

 

 

Data Bits

 

 

 

 

 

 

 

 

7 Data Bits

 

 

 

ON

 

 

 

 

8 Data Bits

 

 

 

OFF

 

 

 

 

Stop Bits

 

 

 

 

 

 

 

 

2 Stop Bits

 

 

 

 

ON

 

 

 

1 Stop Bit

 

 

 

 

OFF

 

 

 

Parity

 

 

 

 

 

ON

OFF

 

Even

 

 

 

 

 

 

Odd

 

 

 

 

 

OFF

ON

 

None

 

 

 

 

 

OFF

OFF

 

Parallel Port

 

 

 

 

 

 

 

 

Centronics Mode

 

 

 

 

 

 

 

OFF

IEEE-1284

 

 

 

 

 

 

 

ON

Communication settings at the printer must match those at the host. Make sure your host is capable of communicating at the speed you select for the printer.