![•GET](/images/new-backgrounds/54811/54811139x1.webp)
•OPT Configure net options, including: sounding, silent network, LQA request, scan rate, home acknowledgment, monitor acknowledgment, occupancy detection, master/slave definitions, AllCall options and tune time.
•GET
•ERAS
Copy all parameters from one network to another. This function is useful if you are defining a new network and wish to base most of its parameters on an existing network, for instance if you need to use different frequencies/channels for day and night communication, but all other net information (such as stations and names) is identical.
Erase an entire network from the ALE data base.
After preparing a set of parameters, your entries are checked and any errors are reported. If you do not correct the detected errors,
Default Values
Unless you define different values, each net uses the following
• | Net Name | No default defined |
• | Self Address | No default defined |
• | AllCall | Send and receive enabled |
• | AllCall Channel | No default defined |
• | Tune Time | No tune time |
• | Silent | No |
• | Home Acknowledgment | Yes |
• | Monitor Acknowledgment | No |
• | Master/Slave | Master |
• | LQA Request | Yes |
• | Sounding | Manual |
• | Occupancy Check | No |
• | Scanned Channels | No default defined. |
When programming a new network or other ALE parameters, you do not need to define all parameters – change only those for which the default values are not suitable.
56_________________________________________________________________________________________________